Trace metal atomic absorption spectrometric analysis utilizing sorbent extraction on polymeric-based supports and renewable reagents
- 1 January 1994
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 119 (7) , 1459-1465
- https://doi.org/10.1039/an9941901459
Abstract
Various methods of analyte preconcentration for atomic absorption spectrometry are available for trace metals in aqueous samples. Among the drawbacks of many of these techniques are the generation of hazardous or toxic wastes, poor preconcentration efficiencies and cumbersome on-line implementation of the particular technique. Preconcentration of trace metals by sorbent extraction utilizing a flow injection method is described. Preconcentration of the analyte is accomplished by its extraction on a solid-phase hydrophobic support prepared by adsorption of a suitable chelating agent. Following extraction of the analyte, the metal–chelate complex is eluted from the solid support by changing the polarity of the carrier stream. The metal systems chosen for examination were copper and lead chelates of diethyldithiocarbamate (DDC) and quinolin-8-ol. Some results are presented for other chelates, namely 4-(2-pyridylazo)resorcinol, 1-(2-pyridylazo)-2-naphthol and dithizone. The sample throughput of the method was 20 h–1 utilizing 2 ml of sample per analysis for preconcentration. The detection limits using the quinolin-8-ol and DDC chelates are at low parts-per-billion levels, with enhancement factors between 50 and 100.Keywords
This publication has 25 references indexed in Scilit:
- Digestion method for the determination of mercury in vegetable matrices by cold vapour atomic absorption spectrometryThe Analyst, 1990
- Flow-injection Donnan dialysis preconcentration of cations for flame atomic absorption spectrophotometryAnalytical Chemistry, 1989
- High efficiency low sample consumption on-line ion-exchange pre-concentration system for flow injection flame atomic absorption spectrometryJournal of Analytical Atomic Spectrometry, 1989
- The determination of copper by flow injection analysis with flame AAS detection after preconcentration by solvent extractionCollection of Czechoslovak Chemical Communications, 1989
- Rapid, On-Line Preconcentration, Matrix Normalization, and Signal Enhancement for Flame Atomic Absorption via Tubular Donnan DialysisApplied Spectroscopy, 1987
- Sample preconcentration by continuous flow extraction with a flow injection atomic absorption detection systemAnalytica Chimica Acta, 1983
- Flow injection analysis for the determination of bismuth by atomic absorption spectrometry with hydride generationAnalytical Chemistry, 1982
- An automated extraction system for flame atomic absorption spectrometryAnalytica Chimica Acta, 1981
- Tubular flow Donnan dialysisAnalytical Chemistry, 1980
- Donnan dialysis enrichment of cationsAnalytical Chemistry, 1977