MR susceptibility misregistration correction
- 1 June 1993
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 12 (2) , 251-259
- https://doi.org/10.1109/42.232253
Abstract
The authors present a new in vivo method to correct the nonlinear, object-shape-dependent and material-dependent spatial distortion in magnetic resonance (MR) images caused by magnetic susceptibility variations. This distortion across the air/tissue interface before and after the correction is quantified using a phantom. The results are compared to the distortion-free computed tomography (CT) images of the same phantom by fusing CT and MR images using fiducials, with a registration accuracy of better than a millimeter. The distortion at the bone/tissue boundary is negligible compared to the typical MRI (MR imaging) resolution of 1 mm, while that at the air/tissue boundary creates displacements of about 2 mm (for G(x) 3.13 mT/m). This is a significant value if MRI is to provide highly accurate geometric measurements, as in the case of target localization for stereotaxic surgery. The correction scheme provides MR images with accuracy similar to that of CT: 1 mm. A new method to estimate the magnetic susceptibility of materials from MR images is presented. The magnetic susceptibility of cortical bone is measured using a SQUID magnetometer, and is found to be -8.86 ppm (with respect to air), which is quite similar to that of tissue (-9 ppm).Keywords
This publication has 20 references indexed in Scilit:
- Multipoint dixon technique for water and fat proton and susceptibility imagingJournal of Magnetic Resonance Imaging, 1991
- Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correctionMagnetic Resonance in Medicine, 1991
- Rapid in vivo proton shimmingMagnetic Resonance in Medicine, 1991
- Magnetic Susceptibility Effects of Trabecular Bone on Magnetic Resonance Imaging of Bone MarrowInvestigative Radiology, 1990
- Magnetic resonance imaging with non-uniform fieldsPhysics in Medicine & Biology, 1986
- The Effects of Bone on Proton NMR Relaxation Times of Surrounding LiquidsInvestigative Radiology, 1986
- Selective Saturation NMR ImagingJournal of Computer Assisted Tomography, 1984
- Image restoration from non-uniform magnetic field influence for direct Fourier NMR imagingPhysics in Medicine & Biology, 1984
- Reconstructing NMR images under magnetic fields with large inhomogeneitiesJournal of Physics E: Scientific Instruments, 1982
- NMR imaging: image recovery under magnetic fields with large non-uniformitiesJournal of Physics E: Scientific Instruments, 1978