Comparison of three high-resolution digitizers for radiochromic film dosimetry
- 26 July 2002
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 29 (8) , 1839-1846
- https://doi.org/10.1118/1.1485056
Abstract
A recently introduced radiographic film scanner from Howtek is evaluated and compared to two other commercially available densitometry systems for its use in radiochromic (RC) film dosimetry in the clinical dose range 0-100 Gy. It has a high-intensity red LED light-source centered at 662 nm (near the major absorption peak for RC film), and is coupled to a CCD linear array detector. This new densitometry system is directly compared to two high-resolution film scanners commonly employed in RC film dosimetry, namely the Lumiscan 75 digitizer (He-Ne laser light source) and the Vidar VXR-16 digitizer (fluorescent light source). A spot densitometer (Nuclear Associates Radiochromic Densitometer) with a filtered 671 nm laser-diode light source is also included as a reference for comparison. The response of the spot densitometer and three high-resolution digitizers is characterized by the dose required to reach a net optical density of 1 (DNOD1), and is 16.0, 37.3, and 46.4 Gy for the Nuclear Associates Radiochromic Densitometer, Howtek MultiRAD 460 and Lumiscan 75 digitizer, respectively. The Vidar VXR-16 does not reach a net optical density of 1. The minimum usable dose at which a 2% level of uncertainty can be achieved (MUD2%) on the three digitizers are 2.6, 6.0, and 38.5 Gy for the Howtek MultiRAD 460, Lumiscan 75, and Vidar VXR-16, respectively. The Howtek MultiRAD 460 shows the greatest sensitivity, lowest MUD2% and best signal-to-noise ratio in the clinical dose range 0-100 Gy. Furthermore, it has no apparent interference (moiré) artifacts that severely limit the low optical density region of the He-Ne laser digitizer. For high-resolution radiochromic dosimetry in the clinical dose range 0-100 Gy, the high-intensity red LED light-source digitizer proves to be the superior modality.Keywords
This publication has 15 references indexed in Scilit:
- The use of an inexpensive red acetate filter to improve the sensitivity of GAFChromic dosimetryMedical Physics, 2001
- Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributionsMedical Physics, 2000
- Predicting optical densitometer response as a function of light source characteristics for radiochromic film dosimetryMedical Physics, 1997
- Comparison of dose response of radiochromic film measured with He-Ne laser, broadband, and filtered light densitometersMedical Physics, 1997
- Dosimetric characteristics of an improved radiochromic filmMedical Physics, 1996
- High‐sensitivity GafChromic film dosimetry for 125I seedMedical Physics, 1994
- Photon energy dependence of the sensitivity of radiochromic film and comparison with silver halide film and LiF TLDs used for brachytherapy dosimetryMedical Physics, 1991
- Sensitometry of the response of a new radiochromic film dosimeter to gamma radiation and electron beamsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1991
- The measurement of absorbed dose and dose gradientsRadiation Physics and Chemistry (1977), 1980
- The response of plastic dosimeters to gamma rays and electrons at high absorbed dose ratesRadiation Physics and Chemistry (1977), 1979