The Behavior of Human Neutrophils During Flow Through Capillary Pores
- 1 August 1990
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 112 (3) , 277-282
- https://doi.org/10.1115/1.2891185
Abstract
The passage times of individual human neutrophils through single capillary-sized pores in polycarbonate membranes were measured with the resistive pulse technique, and results were compared to those obtained from the micropipette aspiration of entire cells. Pore transit measurement serves as a useful means to screen populations of cells, and allows for protocols that measure time dependent changes to the population. Neutrophils exhibited a highly linear pressure/flow rate relationship at aspiration pressures from 200 Pa to 1,500 Pa in both the pore and pipette systems. Cellular viscosity, as determined by the method of Hochmuth and Needham, was 89.0 Pa·s for the pore systems and 134.9 Pa·s for the pipette systems. These results are in general agreement with recent values of neutrophil viscosity published in the literature. Extrapolation of the observed linear flow response revealed an apparent minimum pressure for whole cell aspiration significantly above the threshold pressure predicted by Evans’ liquid drop model. However, whole cell aspiration was achieved in both the pore and pipette systems at pressures below this extrapolated minimum, although the calculated cellular viscosity was greatly increased. The implications of these two regimes of cell deformation is unclear. This behavior could be explained by shear thinning of the material in the cell body. However the origin of this phenomenon may be in the cortical region of the cell, which exhibits an elastic tension that may be deformation rate dependent.Keywords
This publication has 8 references indexed in Scilit:
- On the elasticity of cytoskeletal networksBiophysical Journal, 1988
- Passive Deformation Analysis of Human LeukocytesJournal of Biomechanical Engineering, 1988
- An Investigation of Particle Flow Through Capillary Models With the Resistive Pulse TechniqueJournal of Biomechanical Engineering, 1987
- Analysis of the effects of measured white blood cell entrance times on hemodynamics in a computer model of a microvascular bedPflügers Archiv - European Journal of Physiology, 1985
- Chemotactic peptide-induced changes in neutrophil actin conformation.The Journal of cell biology, 1984
- Quantitative studies on the influence of leukocytes on the vascular resistance in a skeletal muscle preparationMicrovascular Research, 1984
- PASSIVE MATERIAL BEHAVIOR OF GRANULOCYTES BASED ON LARGE DEFORMATION AND RECOVERY AFTER DEFORMATION TESTS1984
- Passive mechanical properties of human leukocytesBiophysical Journal, 1981