CONTRIBUTION FROM THORON ON THE RESPONSE OF PASSIVE RADON DETECTORS
- 1 June 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Health Physics
- Vol. 80 (6) , 612-615
- https://doi.org/10.1097/00004032-200106000-00014
Abstract
In order to evaluate the reliability of measured values of radon concentration, a thoron sensitivity test for passive radon detectors was carried out. To do this test, a thoron chamber system was first set up. The system consists of four parts: an exposure chamber, a gas generator, an environmental monitor, and a measuring device. Five types of radon detectors were examined using the chamber system. After connecting the exposure chamber with the gas generator through an external pump, thoron gas was circulated through the system. The detectors were exposed to thoron-rich air for several days. The mean ratio between thoron and radon concentrations throughout the exposure period was 10:1. Some of the detectors provided values different from the actual radon concentration. Although the presence of thoron can be negligible in most cases, it is necessary to check the thoron contribution to the detector response with the proposed or similar test before practical use.Keywords
This publication has 12 references indexed in Scilit:
- Preliminary Survey on Radon and Thoron Concentrations in KoreaRadiation Protection Dosimetry, 1998
- Nationwide Indoor Radon Survey in Japan.Japanese Journal of Health Physics, 1997
- Some Problems on the Measurement of 222Rn Concentrations by Passive Cup MethodHealth Physics, 1995
- A Method for Determining Soil Gas 220Rn (Thoron) ConcentrationsHealth Physics, 1995
- An instrument for continuous measurement of 220Rn (and 222Rn) using delayed coincidences between 220Rn and 216PoNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994
- Characterization of Japanese Wooden Houses With Enhanced Radon and Thoron ConcentrationsHealth Physics, 1994
- The Passive Radon-Thoron Discriminative Dosimeter for Practical Use.Japanese Journal of Health Physics, 1994
- Spatial Distribution of Thoron and Radon Concentrations in the Indoor Air of A Traditional Japanese Wooden HouseHealth Physics, 1994
- Measurements of 222Rn in Air Using a Flow-Through Lucas Cell and Multiple Time Analysis of Recorded Pulse EventsRadiation Protection Dosimetry, 1992
- An Electrostatic Integrating 222Rn Monitor with Cellulose Nitrate Film for Environmental MonitoringHealth Physics, 1988