Estimation of effective dose in some digital angiographic and interventional procedures.
- 1 January 1998
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 71 (841) , 42-47
- https://doi.org/10.1259/bjr.71.841.9534698
Abstract
In general, effective dose values for similar interventional vascular radiology (IVR) procedures are different. This is due to problems with the classification of radiological procedures, which make comparisons difficult. Patient size, examination technique and clinical condition as well as the skill of the medical radiologists also affect effective dose. Currently, there is a broad agreement on the classification of similar procedures so that effective dose estimates can be made from measurements of the dose area product (DAP). Thus, reference dose values may be established and comparative studies between different services and hospitals can be made. The objective of this study is to provide dose data for some digital angiographic and interventional procedures. Values of measured DAP for 143 patients for five types of procedures are presented. Procedures investigated were abdominal angiography, arteriography of lower limbs, biliary drainage, embolization of spermatic vein and nephrostomy. All the procedures were performed using digital equipment. Values of DAP and effective dose were 30 Gy cm2 and 6.2 mSv for arteriography of lower limbs and 150 Gy cm2 and 38.2 mSv for biliary drainage. In each one of these procedures, effective dose values per minute of fluoroscopy and per radiography film have been calculated. It is possible to use this information for the rapid estimation of effective dose.Keywords
This publication has 9 references indexed in Scilit:
- A patient dose survey for femoral arteriogram diagnostic radiographic examinations using a dose - area product meterPhysics in Medicine & Biology, 1996
- Patient dose values in interventional radiologyThe British Journal of Radiology, 1995
- The impact of digital imaging on patient doses during barium studiesThe British Journal of Radiology, 1995
- Assessment of organ radiation doses and associated risk for digital bifemoral arteriographyThe British Journal of Radiology, 1995
- Patient and staff dosimetry in neuroradiological proceduresThe British Journal of Radiology, 1995
- Radiation-induced temporary epilation after a neuroradiologically guided embolization procedure.Radiology, 1994
- Patient doses received during digital subtraction angiographyThe British Journal of Radiology, 1993
- IntroductionAnnals of the ICRP, 1991