The dosimetric effect of inhomogeneity correction in dynamic conformal arc stereotactic body radiation therapy for lung tumors
Open Access
- 1 March 2006
- journal article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 7 (2) , 58-63
- https://doi.org/10.1120/jacmp.v7i2.2236
Abstract
For patients treated with lung stereotactic body radiation therapy (SBRT) using dynamic conformal arcs, the influence of inhomogeneity correction (IC) on normal tissue and tumor dosimetry was studied. For the same numbers of monitor units, the planning target volume equivalent uniform doses calculated without path-length IC were lower than those calculated with IC (mean difference 18%, range 1-34%; p < 0.0001). Normal lung dose differences were of the same magnitude in opposite direction. In reports of SBRT, it will be helpful to maintain clear communication about the type of IC used to avoid future uncertainties about true normal tissue tolerance and tumor dose-response relationships.Keywords
This publication has 9 references indexed in Scilit:
- A phase I/II trial of stereotactic body radiation therapy (SBRT) for lung metastases: Initial report of dose escalation and early toxicityInternational Journal of Radiation Oncology*Biology*Physics, 2006
- Stereotactic body radiation therapy of early-stage non–small-cell lung carcinoma: Phase I studyInternational Journal of Radiation Oncology*Biology*Physics, 2005
- Influence of calculation model on dose distribution in stereotactic radiotherapy for pulmonary targetsInternational Journal of Radiation Oncology*Biology*Physics, 2005
- American Society for Therapeutic Radiology and Oncology* and American College of Radiology Practice Guideline for the Performance of Stereotactic Body Radiation TherapyInternational Journal of Radiation Oncology*Biology*Physics, 2004
- How should we describe the radiobiologic effect of extracranial stereotactic radiosurgery: Equivalent uniform dose or tumor control probability?Medical Physics, 2003
- Monte Carlo dose verification for intensity-modulated arc therapyPhysics in Medicine & Biology, 2001
- Applying the equivalent uniform dose formulation based on the linear-quadratic model to inhomogeneous tumor dose distributions: Caution for analyzing and reportingJournal of Applied Clinical Medical Physics, 2000
- Heterogeneity corrections should be used in treatment planning for lung cancerMedical Physics, 2000
- Reporting and analyzing dose distributions: A concept of equivalent uniform doseMedical Physics, 1997