Enzymatic Microreactor-on-a-Chip: Protein Mapping Using Trypsin Immobilized on Porous Polymer Monoliths Molded in Channels of Microfluidic Devices
Top Cited Papers
- 3 July 2002
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (16) , 4081-4088
- https://doi.org/10.1021/ac020180q
Abstract
Enzymatic microreactors have been prepared in capillaries and on microfluidic chips by immobilizing trypsin on porous polymer monoliths consisting of 2-vinyl-4,4-dimethylazlactone, ethylene dimethacrylate, and acrylamide or 2-hydroxyethyl methacrylate. The azlactone functionalities react readily with amine and thiol groups of the enzyme to form stable covalent bonds. The optimized porous properties of the monoliths lead to very low back pressures enabling the use of simple mechanical pumping to carry out both the immobilization of the enzyme from its solution and the subsequent analyses of substrate solutions. The Michealis−Menten kinetic characteristics of the reactors were probed using a low molecular weight substrate: N-α-benzoyl-l-arginine ethyl ester. The effects of immobilization variables such as the concentration of trypsin in solution and percentage of azlactone functionalities in the monolith, as well as the effect of reaction time on the enzymatic activity, and of process variables such as substrate flow velocity and residence time in the reactor, were studied in detail. The proteolytic activity of the enzymatic microreactor on chip was demonstrated at different flow rates with the cleavage of fluorescently labeled casein used as a substrate. The excellent performance of the monolithic microreactor was also demonstrated with the digestion of myoglobin at the fast flow rate of 0.5 μL/min, which affords a residence time of only 11.7 s. The digest was then characterized using MALDI-TOF MS, and 102 out of 153 possible peptide fragments were identified giving a sequence coverage of 67%.Keywords
This publication has 32 references indexed in Scilit:
- Product Review: Flow injection Analysis; Quietly Pushing AheadAnalytical Chemistry, 2002
- Bi-enzymatic and capillary electrophoretic analysis of non-fluorescent compounds in microfluidic devicesSensors and Actuators B: Chemical, 2002
- Determination of Carcinoembryonic Antigen in Human Sera by Integrated Bead-Bed Immunoasay in a Microchip for Cancer DiagnosisAnalytical Chemistry, 2001
- Application of Convective Interaction Media disks with immobilised glucose oxidase for on-line glucose measurementsAnalytica Chimica Acta, 2000
- Chip-based nanovials for tryptic digest and capillary electrophoresisAnalytica Chimica Acta, 1999
- Handling of Picoliter Liquid Samples in a Poly(dimethylsiloxane)-Based Microfluidic DeviceAnalytical Chemistry, 1999
- Porous silicon as the carrier matrix in microstructured enzyme reactors yielding high enzyme activitiesJournal of Micromechanics and Microengineering, 1997
- Enhanced enzyme activity in silicon integrated enzyme reactors utilizing porous silicon as the coupling matrixSensors and Actuators B: Chemical, 1996
- Immobilization of trypsin onto “molded” macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate) rods and use of the conjugates as bioreactors and for affinity chromatographyBiotechnology & Bioengineering, 1996
- Continuous rods of macroporous polymer as high-performance liquid chromatography separation mediaAnalytical Chemistry, 1992