Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry
- 1 March 1998
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 43 (3) , 695-702
- https://doi.org/10.1088/0031-9155/43/3/019
Abstract
A simple methodology for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry is presented to enable individuals to undertake such work in a routine clinical environment. Samples of PAG were irradiated using a linear accelerator and imaged using a 0.5 T (22 MHz) Philips Gyroscan MRI scanner. The mean spin-lattice relaxation rate was measured using a 'turbo-mixed' sequence, consisting of a series of 90 degrees pulses, each followed by acquisition of a train of spin echoes. The mean sensitivity for five different batches of PAG in the range up to 10 Gy was calculated to be 0.0285 s-1 Gy-1 for the mean spin-lattice relaxation rate with a percentage standard deviation of 1.25%. The overall reproducibility between batches was calculated to be 2.69%. This methodology, which introduces the novel use of pre-filled nitrogen vials for calibration, has been used to develop techniques for filling anatomically shaped anthropomorphic phantoms.Keywords
This publication has 12 references indexed in Scilit:
- Fast T1 imaging of dual gel samples for diffusion measurements in NMR dosimetry gelsMagnetic Resonance Imaging, 1997
- Radiation therapy dosimetry using magnetic resonance imaging of polymer gelsMedical Physics, 1996
- Diffusion in Fe(II/III) radiation dosimetry gels measured by magnetic resonance imagingPhysics in Medicine & Biology, 1995
- Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeterPhysics in Medicine & Biology, 1994
- Dose-response curve slope improvement and result reproducibility of ferrous-sulphate-doped gels analysed by NMR imagingPhysics in Medicine & Biology, 1994
- NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3D dosimetry by MRIMagnetic Resonance Imaging, 1993
- Diffusion of ferric ions in agarose dosimeter gelsPhysics in Medicine & Biology, 1992
- Dose-response curves for Fricke-infused agarose gels as obtained by nuclear magnetic resonancePhysics in Medicine & Biology, 1990
- RLSQ: T1, T2, and ρ calculations, combining ratios and least squaresMagnetic Resonance in Medicine, 1987
- Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imagingPhysics in Medicine & Biology, 1984