Tricuspid valve replacement with the St. Jude Medical valve: 19 years of experience
Open Access
- 1 November 2000
- journal article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 18 (5) , 565-569
- https://doi.org/10.1016/s1010-7940(00)00570-4
Abstract
Objective: The choice of the valve substitute in the tricuspid position remains controversial. A St. Jude Medical valve is a choice of valve substitute and its lower thrombogenicity and excellent hemodynamic performance have been reported even in the tricuspid position. However, little is known of the long-term durability of the St. Jude Medical valve in the tricuspid position. Our long-term experience of tricuspid valve replacement showed the higher thrombogenicity than we had expected, therefore, this study was done to reconsider our strategy for valve choice. Methods: This study reviewed 23 patient who underwent 25 tricuspid valve replacements with the St. Jude Medical valves from 1980 to 1997. The mean age was 40 years. Eleven patients (48%) were men. There were four in-hospital deaths (17%). The remaining 19 patients were all alive and followed from 2.2 to 19.0 years (mean 11.8 years). Results: The overall survival, including hospital mortality, was 83%, 10 and 15 years after surgery. Valve thrombosis occurred in six patients. Freedom from valve thrombosis was 78 and 70%, 10 and 15 years after surgery, respectively. The linearized rate of the valve thrombosis was 2.9%/patient-years. Six patients required reoperation. The mean interval to reoperation was 9.5 years. Freedom from reoperation was 83% and 75%, 10 and 15 years after surgery, respectively. The linearized rate of the reoperation was 2.8%/patient-years. No structural valve deterioration was found. Echocardiographic study showed that the function of the St. Jude Medical valve without valve-related complications was well maintained. Conclusions: The higher thrombogenicity of the St. Jude Medical valve in the tricuspid position altered our choice of valve substitutes from the St. Jude Medical valve to a bioprosthesis which is lack of need for anticoagulant therapy except for juvenile patients who are able to maintain potent anticoagulant therapy.Keywords
This publication has 15 references indexed in Scilit:
- Tricuspid valve replacement: UK heart valve registry mid-term results comparing mechanical and biological prosthesesThe Annals of Thoracic Surgery, 1998
- Is a Bioprosthesis Preferable in Tricuspid Valve Replacement?The Thoracic and Cardiovascular Surgeon, 1996
- Tricuspid valve replacement: Fifteen years of experience with mechanical prostheses and bioprosthesesThe Journal of Thoracic and Cardiovascular Surgery, 1995
- Long-term results of valve replacement with the St. Jude Medical prosthesisThe Journal of Thoracic and Cardiovascular Surgery, 1995
- The valve choice in tricuspid valve replacement: 25 years of experienceEuropean Journal of Cardio-Thoracic Surgery, 1995
- Tricuspid valve replacement with the St. Jude Medical valveSurgery Today, 1994
- Long-term results of St. Jude Medical valve in the tricuspid positionThe Annals of Thoracic Surgery, 1992
- Late thrombosis of the Björk-Shiley tilting disc valve in the tricuspid positionThe Journal of Thoracic and Cardiovascular Surgery, 1986
- Follow-up Assessment of St. Jude Medical Prosthetic Valve in the Tricuspid Position: Clinical and Hemodynamic ResultsThe Annals of Thoracic Surgery, 1984
- Long-term results of tricuspid valve replacement and the problem of prosthetic valve thrombosisThe American Journal of Cardiology, 1983