Effect of bladder volume on measured intravesical pressure: a prospective cohort study
Open Access
- 6 July 2006
- journal article
- research article
- Published by Springer Nature in Critical Care
- Vol. 10 (4) , R98
- https://doi.org/10.1186/cc4962
Abstract
Introduction: Correct bedside measurement of intra-abdominal pressure (IAP) is important. The bladder method is considered as the gold standard for indirect IAP measurement, but the instillation volumes reported in the literature vary substantially. The aim of this study was to evaluate the effect of instillation volume on intra-bladder pressure (IBP) as an estimation for IAP in critically ill patients. Methods: In this prospective cohort study in 13 sedated and mechanically ventilated patients, we used a revised closed system repeated measurement technique for measurement of IBP. After the system was flushed, IBP was measured with 25 ml increments up to 300 ml. The absolute bias for each volume was calculated as IBP at a given volume minus IBP at zero volume. Results: In total, 30 measurement sets were performed (mean 2.3 per patient). The median IBP at 25 ml was already significantly higher than IBP at zero volume (7.5 versus 6 mmHg). There was no correlation between IBP at zero volume and absolute IBP bias at any bladder volume. Median absolute IBP bias was 1.5 mmHg at 50 ml; 2.5 mmHg at 100 ml; 5.5 mmHg at 150 ml; and up to 11 mmHg at 300 ml. Conclusion: Larger instillation volumes than the usually recommended 50 ml to estimate IAP by bladder pressure may cause clinically relevant overestimation of IAP. Small volumes to a maximum of 25 ml, enough to create a fluid column and to remove air, may be sufficient.Keywords
This publication has 11 references indexed in Scilit:
- Saline volume in transvesical intra-abdominal pressure measurement: enough is enoughIntensive Care Medicine, 2006
- Correlation between intra-abdominal and intracranial pressure in nontraumatic brain injuryIntensive Care Medicine, 2005
- Intra-abdominal hypertension in the critically ill: it is time to pay attentionCurrent Opinion in Critical Care, 2005
- Incidence and prognosis of intraabdominal hypertension in a mixed population of critically ill patients: A multiple-center epidemiological study*Critical Care Medicine, 2005
- Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisalIntensive Care Medicine, 2004
- Bench-to-bedside review: Chest wall elastance in acute lung injury/acute respiratory distress syndrome patientsCritical Care, 2004
- Both Primary and Secondary Abdominal Compartment Syndrome can be Predicted Early and are Harbingers of Multiple Organ FailurePublished by Wolters Kluwer Health ,2003
- Intra-abdominal pressure monitoring in liver transplant recipients: a prospective studyIntensive Care Medicine, 2003
- Blood Flow, Pressure and Compliance in the Male Human BladderJournal of Urology, 2002
- Estimation of Intra-abdominal Pressure by Bladder Pressure Measurement: Validity and MethodologyThe Journal of Trauma: Injury, Infection, and Critical Care, 2001