Optimization of Ag isotope-ratio precision with a 128-Channel array detector coupled to a Mattauch-Herzog mass spectrograph
- 16 October 2009
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 25 (3) , 322-327
- https://doi.org/10.1039/b914052b
Abstract
Isotope-ratio measurements are necessary in a wide range of applications. The precision of these measurements is of utmost importance because it governs the ability to distinguish differences between samples. Often, simultaneous isotope detection is necessary to reach the precision values needed for an analysis to be conclusive. Furthermore, the more isotope ratios that can be precisely determined at once, the better the chances of distinguishing between samples. Therefore, detector arrays, able to simultaneously monitor a broad range of isotopes, are attractive. Such an array detector, termed the focal plane camera (FPC), has been shown to be capable of achieving impressive precision values (0.02% RSD) within relatively short integration times (200 s). However, because the channels of the FPC array detector are inherently discrete, optimization of peak integration methods is important. This paper compares isotope-ratio precision values based on different peak integration methods of raw and zero-filled interpolated data. Also, problems associated with peak drift are explored and the use of flat-topped peak shapes for improved isotope-ratio precision levels are investigated.Keywords
This publication has 18 references indexed in Scilit:
- Isotope Ratio Determination in the Earth and Environmental Sciences: Developments and Applications in 2006–2007Geostandards and Geoanalytical Research, 2008
- RADIOCARBON DATING: REVOLUTIONS IN UNDERSTANDING*Archaeometry, 2008
- Characterization of a Second-Generation Focal-Plane Camera Coupled to an Inductively Coupled Plasma Mattauch−Herzog Geometry Mass SpectrographAnalytical Chemistry, 2006
- Forensic applications of isotope ratio mass spectrometry—A reviewForensic Science International, 2006
- Recent advances in detector-array technology for mass spectrometryInternational Journal of Mass Spectrometry, 2004
- Characterization of a Focal Plane Camera Fitted to a Mattauch−Herzog Geometry Mass Spectrograph. 2. Use with an Inductively Coupled PlasmaAnalytical Chemistry, 2004
- Development and characterization of an electrostatic quadrupole extraction lens for mass spectrometryJournal of Analytical Atomic Spectrometry, 2003
- 146Sm–142Nd evidence from Isua metamorphosed sediments for early differentiation of the Earth's mantleNature, 2003
- Evolution and revolution in instrumentation for plasma-source mass spectrometryPublished by Walter de Gruyter GmbH ,2001
- Fourier domain interpolation of sampled spectral signalsAnalytical Chemistry, 1976