Physical measurements of bilayer-skeletal separation forces
- 1 May 1995
- journal article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 23 (3) , 308-321
- https://doi.org/10.1007/bf02584431
Abstract
Bilayer membranes are intrinsically fluid in character and require stabilization by association with an underlying cytoskeleton. Instability either in the membrane-associated cytoskeleton or in the association between the bilayer and the skeleton can lead to loss of membrane bilayer and premature cell death. In this report measurements of the physical strength of the association between membrane bilayer and the membrane-associated skeleton in red blood cells are reported. These measurements involve the mechanical formation of long, thin cylinders of membrane bilayer (tethers) from the red cell surface. ultrastructural evidence is presented indicating that these tethers do not contain membrane skeleton and, furthermore, that they are deficient in at least some integral membrane proteins. By measuring the forces on the cell as the tether is formed and the dimensions of the tether, the energy associated with its formation can be calculated. The minimum force to form a tether was found to be ≈50 pN corresponding to an energy of dissociation of 0.2–0.3 mJ/m2. Such measurements enable critical evaluation of potential physical mechanisms for the stabilization of the membrane bilayer by the underlying cytoskeleton. It is postulated that an important contribution to the energy of association between bilayer and skeleton comes from the increase in chemical potential due to the lateral segregation of lipids and integral proteins.Keywords
This publication has 36 references indexed in Scilit:
- Uncoupling of the Spectrin-Based Skeleton from the Lipid Bilayer in Sickled Red CellsScience, 1991
- Decreased membrane mechanical stability and in vivo loss of surface area reflect spectrin deficiencies in hereditary spherocytosis.Journal of Clinical Investigation, 1988
- Reductions of erythrocyte membrane viscoelastic coefficients reflect spectrin deficiencies in hereditary spherocytosis.Journal of Clinical Investigation, 1988
- Inheritance Pattern and Clinical Response to Splenectomy as a Reflection of Erythrocyte Spectrin Deficiency in Hereditary SpherocytosisNew England Journal of Medicine, 1986
- Structure and function of the cytoplasmic domain of band 3: center of erythrocyte membrane—peripheral protein interactionsBiochimica et Biophysica Acta (BBA) - Reviews on Biomembranes, 1986
- Restoration of normal membrane stability to unstable protein 4.1-deficient erythrocyte membranes by incorporation of purified protein 4.1.Journal of Clinical Investigation, 1986
- Temperature dependence of the yield shear resultant and the plastic viscosity coefficient of erythrocyte membrane. Implications about molecular events during membrane failureBiophysical Journal, 1982
- Extensional flow of erythrocyte membrane from cell body to elastic tether. I. AnalysisBiophysical Journal, 1982
- Viscosity of human red cell membrane in plastic flowMicrovascular Research, 1976
- Shear flow over a protrusion from a plane wallJournal of Biomechanics, 1972