In Vitro Investigation of Gallstones with Computed Tomography
- 1 December 1980
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 4 (6) , 827-831
- https://doi.org/10.1097/00004728-198012000-00015
Abstract
An in vitro investigation of gallstones from 25 patients using computed tomography (CT) was performed. An abdominal phantom was constructed and filled with a matrix with an attenuation value equivalent to normal liver. A condom filled with water and positioned within the phantom simulated the gallbladder. Gallstones were placed in the condom and were scanned, radiographed, measured and inspected. All gallstones were detectable by CT as filling defects within the condom having CT attenuation values higher or lower than water. Attenuation values ranged from +178 to -188CT units (scale, +500 to -500). Gallstones containing Ca settled to the bottom of the condom, while calculi containing gas filled fissures rose to the top.Keywords