A vector Wiener filter for dual-radionuclide imaging
- 1 October 1996
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 15 (5) , 700-709
- https://doi.org/10.1109/42.538947
Abstract
The routine use of a single radionuclide for patient imaging in nuclear medicine can be complemented by studies employing two tracers to examine two different processes in a single organ, most frequently by simultaneous imaging of both radionuclides in two different energy windows. In addition, simultaneous transmission/emission imaging with dual-radionuclides has been described, with one radionuclide used for the transmission study and a second for the emission study. There is thus currently considerable interest in dual-radionuclide imaging. A major problem with all dual-radionuclide imaging is the "crosstalk" between the two radionuclides. Such crosstalk frequently occurs, because scattered radiation from the higher energy radionuclide is detected in the lower energy window, and because the lower energy radionuclide may have higher energy emissions which are detected in the higher energy window. The authors have previously described the use of Fourier-based restoration filtering in single photon emission computed tomography (SPECT) and positron emission tomography (PET) to improve quantitative accuracy by designing a Wiener or other Fourier filter to partially restore the loss of contrast due to scatter and finite spatial resolution effects. The authors describe here the derivation and initial validation of an extension of such filtering for dual-radionuclide imaging that simultaneously 1) improves contrast in each radionuclide's "direct" image, 2) reduces image noise, and 3) reduces the crosstalk contribution from the other radionuclide. This filter is based on a vector version of the Wiener filter, which is shown to be superior [in the minimum mean square error (MMSE) sense] to the sequential application of separate crosstalk and restoration filters.Keywords
This publication has 18 references indexed in Scilit:
- A new dual‐isotope convolution cross‐talk correction method: A TL‐201/TC‐99m SPECT cardiac phantom studyMedical Physics, 1994
- Feasibility of dual radionuclide brain imaging with I‐123 and Tc‐99 mMedical Physics, 1994
- A general framework for frequency domain multi-channel signal processingIEEE Transactions on Image Processing, 1993
- Measurement of Radiotracer Concentration in Brain Gray Matter Using Positron Emission Tomography: MRI-Based Correction for Partial Volume EffectsJournal of Cerebral Blood Flow & Metabolism, 1992
- Efficient multiframe Wiener restoration of blurred and noisy image sequencesIEEE Transactions on Image Processing, 1992
- Digital restoration of multichannel imagesIEEE Transactions on Acoustics, Speech, and Signal Processing, 1989
- Stochastic Processes in Engineering SystemsPublished by Springer Nature ,1985
- Karhunen-Loeve multispectral image restoration, part I: TheoryIEEE Transactions on Acoustics, Speech, and Signal Processing, 1984
- A Wiener filter for nuclear medicine imagesMedical Physics, 1983
- Lectures on Wiener and Kalman FilteringPublished by Springer Nature ,1981