Field measurement of splice loss applying the backscattering method

Abstract
A method it proposed to measure mean splice loss applying the back-scattering method from one end of the fibre link only. To eliminate the influence of the difference in back-scattering properties of the spliced fibres, each backscattering coefficient is measured separately beforehand.