OCCURRENCE AND PARAMETERS OF FREQUENCY OF LEGIONELLA IN WARM WATER-SYSTEMS OF HOSPITALS AND HOTELS IN LOWER SAXONY
- 1 March 1988
- journal article
- research article
- Vol. 186 (1) , 79-88
Abstract
A total of 1241 water samples was investigated from 103 hospitals and 62 hotels in Lower Saxony 1985-87. 331 of 949 samples from hospitals and 26 of 292 samples from hotels were Legionella positive. All together 70% of the hospitals and 18% of the hotels investigated were Legionella positive, and 836 strains of Legionella were isolated (Table 1). As they could be diagnosed they belong to L. pneumophila SG1 306 strains, SG2 36 strains, SG3 127 strains, SG4 45 strain, SG5 29 strain, SG6 106 strains, SG9 13 strains and SG10 13 strains. Further 134 strains belonging to L. pneumophila but not to SG1-SG12 show cross reactions with serogroups 5, 8, and 10. Finally, 16 strains belong to L. dumoffii and 1 strain to L. anisa (Table 2). The following parameters of water samples were studied, too: temperature, pH value, conductivity, concentration of iron, of organic matter, of other bacteria, occurrence of amoebas, and the materials of water plumbing systems. Most samples contained concentrations of Legionella in the range of 101-103 CFU/ml, highest concentrations were 105 CFU/ml (Fig. 1). Most frequently, Legionella were isolated within the range of temperature of 35-45.degree. C. However, a few of the water samples were positive for Legionella even up to 66.degree. C (Fig. 3). The conductivity has no and the pH value (Fig. 2) has only little influence on the occurrence of Legionella. There is a positive correlation between concentration of iron and frequency of Legionella (Fig. 4). Also organic matter (Fig. 6) and amoebas (Table 3) seem to enhance the occurrence of Legionella. Plumbing systems consisting of copper showed an inhibitory effect on Legionella during the first five years, whereas no effect could be detected in older systems (Fig. 5).This publication has 9 references indexed in Scilit:
- Effects of metals on Legionella pneumophila growth in drinking water plumbing systemsApplied and Environmental Microbiology, 1985
- Prevalence and Significance of Legionella pneumophila Contamination of Residential Hot-Tap Water SystemsThe Journal of Infectious Diseases, 1985
- Identification of 22 Legionella species and 33 serogroups with the slide agglutination testJournal of Clinical Microbiology, 1985
- LEGIONELLA PNEUMOPHILA IN WATER PLUMBING SYSTEMSThe Lancet, 1982
- Improved semiselective medium for isolation of Legionella pneumophila from contaminated clinical and environmental specimensJournal of Clinical Microbiology, 1981
- INVESTIGATION AND CONTROL OF AN OUTBREAK OF LEGIONNAIRES' DISEASE IN A DISTRICT GENERAL HOSPITALThe Lancet, 1981
- Isolation of Legionella pneumophila from water systems: methods and preliminary results.BMJ, 1981
- Isolation of Legionella pneumophila from Hospital Shower HeadsAnnals of Internal Medicine, 1981
- LEGIONNAIRES' DISEASE IN A TRANSPLANT UNIT: ISOLATION OF THE CAUSATIVE AGENT FROM SHOWER BATHSThe Lancet, 1980