Interpretation of the electrocardiogram in suspected myocardial infarction: a randomized controlled study of the effect of a training programme to reduce interobserver variation
- 1 April 1992
- journal article
- clinical trial
- Published by Wiley in Journal of Internal Medicine
- Vol. 231 (4) , 407-412
- https://doi.org/10.1111/j.1365-2796.1992.tb00952.x
Abstract
We examined the effect of a training programme to reduce interobserver variation in interpretation of electrocardiography in suspected myocardial infarction. Sixteen doctors with 6-24 months of clinical training in internal medicine read serial electrocardiographic recordings in 107 patients and assessed whether signs indicative of acute myocardial infarction were present. There was disagreement in approximately 70% of cases. Eight of the doctors were randomly allocated to attend an 8-h intensive course on interpretation of electrocardiography in myocardial infarction. The remaining eight participants were allocated to a control group, received no training, and were not told about the subject of the study. All the doctors then reviewed another series of electrocardiographic recordings. No difference was found in the level of agreement within the two groups before and after the training programme, or between the two groups before and after the training. The raters' ability to discriminate between electrocardiograms with a high and low indication of infarction remained unaffected. We conclude that the training programme did not increase agreement regarding the interpretation of electrocardiographic data in suspected myocardial infarction. Our results suggest that the diagnostic approach of physicians is established at a very early stage in their clinical training. The effect of training programmes should be evaluated by the use of randomized clinical studies.Keywords
This publication has 12 references indexed in Scilit:
- Interobserver variation of angioscintigraphy for deep vein thrombosisScandinavian Journal of Clinical and Laboratory Investigation, 1987
- Mammography is an Objective Diagnostic MethodActa Radiologica. Diagnosis, 1984
- The Reliability of Medical History and Physical Examination in Patients with Acute Abdominal PainMethods of Information in Medicine, 1983
- Inter‐observer variation of symptoms and signs in jaundiceLiver International, 1981
- Observer variation in the interpretation of lower limb venogramsAmerican Journal of Roentgenology, 1979
- The Reliability of Clinical Methods, Data and JudgmentsNew England Journal of Medicine, 1975
- The Reliability of Clinical Methods, Data and JudgmentsNew England Journal of Medicine, 1975
- Reliability of Physical Signs in Patients with Severe Attacks of Ulcerative ColitisBMJ, 1971
- Gastroduodenal X-Ray Diagnosis: A Comparison of Radiographic Technics and InterpretationsRadiology, 1960
- OBSERVER VARIATION IN REPORTS ON ELECTROCARDIOGRAMSHeart, 1958