Source localization from axial image sets by iterative relaxation of the nearest neighbor criterion
- 7 September 1999
- journal article
- Published by Wiley in Medical Physics
- Vol. 26 (9) , 1919-1924
- https://doi.org/10.1118/1.598717
Abstract
The use of axial image sets has become widely used to localize interstitial brachytherapy sources. One application of this method of localization is to perform post-implant dosimetry following transperineal interstitial permanent prostate brachytherapy (TIPPB) where the target structure and the source locations are displayed on the same image. The design of an appropriate scanning sequence often results in abutting slices of an intermediate slice width (3, 4, or 5 mm). Because a single source may be imaged on more than one slice, the resultant scans always show many more source locations than actual sources implanted. The physicist is then faced with the tedious task of determining which sources appear on more than one slice and deciding which source locations to eliminate from the data set. We have developed an algorithm, similar to one employed by Roy et al., which automates this process by relaxing the nearest neighbor criterion until the number of sources is reduced to either the number of sources implanted or the number counted on a projection radiograph. This paper details this algorithm and the results of its application to phantom studies, comparing to known source locations, as well as clinical studies, comparing to orthogonal film source localization, on a series of ten patients. Phantom studies demonstrate the superiority of the algorithm over orthogonal film reconstruction, locating 100% of the sources within 5 mm of the actual location as compared to 66% for the paired radiographs. The clinical study findings are commensurate with these results, with 72% of the sources on average located within 5 mm of the corresponding source in the other data set. The positive correlation of the quality of the orthogonal film reconstruction results with the quality of the coregistration results suggests that differences in registration between the two data sets may be due primarily to the uncertainties in the orthogonal film reconstruction.Keywords
This publication has 18 references indexed in Scilit:
- Clinical Impact of Implementing the Recommendations of AAPM Task Group 43 on Permanent Prostate Brachytherapy Using 125IInternational Journal of Radiation Oncology*Biology*Physics, 1998
- Comparison of MRI- and CT-based post-implant dosimetric analysis of transperineal interstitial permanent prostate brachytherapyRadiation Oncology Investigations, 1998
- Evaluation of permanent I-125 prostate implants using radiography and magnetic resonance imagingInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Moldable tissue equivalent bolus for high-energy photon and electron therapyMedical Physics, 1996
- A new source localization algorithm with no requirement of one‐to‐one source correspondence between biplane radiographsMedical Physics, 1996
- Semiautomated matching and seed position location for implanted ribbonsMedical Physics, 1994
- A CT-based evaluation method for permanent implants: application to prostateInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Computed tomography treatment planning in IR-192 brachytherapy in the head and neckInternational Journal of Radiation Oncology*Biology*Physics, 1992
- Two-film brachytherapy reconstruction algorithmMedical Physics, 1985
- Rapid, accurate, three-dimensional location of multiple seeds in implant radiotherapy treatment planningPhysics in Medicine & Biology, 1983