Abstract
“Single shot” magnetic resonance (MR) diffusion imaging was used to study the details of signal decay curves in experimental perturbations of cerebral perfusion induced by hypercapnia or death. Despite large perfusion increases observed with dynamic susceptibility-contrast MR imaging, no correlation with these changes was seen in either the diffusion coefficient or any other intravoxel incoherent motion (IVIM) model parameters in dog gray matter as arterial carbon dioxide pressure increased. Non-monoexponential signal decay in cat gray matter was seen both before and after death. In addition, cat gray matter demonstrated a steady decrease in the diffusion coefficient after death. These data are strong evidence that the fast component of the non-monoexponential diffusion-related signal decay is not due solely to perfusion. The authors believe that a second compartment of nonex-changing spins, most likely cerebrospinal fluid, accounts for the non-monoexponential decay.Keywords
This publication has 28 references indexed in Scilit:
- Detection of pseudodiffusion in rat brain following blood substitution with perfluorocarbonJournal of Magnetic Resonance (1969), 1992
- Echo‐planar imaging of diffusion and perfusionMagnetic Resonance in Medicine, 1991
- Studies of restricted diffusion in heterogeneous media containing variations in susceptibilityMagnetic Resonance in Medicine, 1991
- The use of gradient flow compensation to separate diffusion and microcirculatory flow in MRIMagnetic Resonance in Medicine, 1991
- Quantitative measurement of tissue perfusion and diffusion in vivoMagnetic Resonance in Medicine, 1991
- Single-shot diffusion imaging at 2.0 teslaJournal of Magnetic Resonance (1969), 1990
- Anatomic segmentation and volumetric calculations in nuclear magnetic resonance imagingIEEE Transactions on Medical Imaging, 1989
- Instant images of the body by magnetic resonanceMagnetic Resonance in Medicine, 1987
- Regional Cerebral Blood Volume and Hematocrit Measured in Normal Human Volunteers by Single-Photon Emission Computed TomographyJournal of Cerebral Blood Flow & Metabolism, 1985
- The Effects of Changes in Pa CO 2 Cerebral Blood Volume, Blood Flow, and Vascular Mean Transit TimeStroke, 1974