Abstract
OBJECTIVE: To investigate the bacteriological safety of preprepared endotracheal tubes in accident and emergency departments. METHODS: Swabs were taken and cultured from luminal and exterior surfaces of every preprepared exposed endotracheal tube in a hospital resuscitation room. RESULTS: Coagulase negative staphylococci (common skin commensals) were isolated from 50% of the tubes. No other bacteria were isolated. CONCLUSIONS: The practice of leaving preprepared airway equipment exposed in the resuscitation room is unlikely to contribute to the development of nosocomial pneumonia, provided the equipment is kept dry and that personnel minimize handling.Keywords
This publication has 5 references indexed in Scilit:
- Contribution of Water Condensation in Endotracheal Tubes to Contamination of the LungsChest, 1993
- Manual Ventilation Bags as a Source for Bacterial Colonization of Intubated PatientsAmerican Review of Respiratory Disease, 1990
- Nosocomial pneumonia in the intubated patient: Role of gastric colonizationEuropean Journal of Clinical Microbiology & Infectious Diseases, 1989
- The Incidence of Nosocomial Pneumonia Following Urgent Endotracheal IntubationInfection Control, 1987
- Nosocomial infections in a respiratory intensive care unitCritical Care Medicine, 1987