Calculation of Dose Distributions for Iridium-192 Implants
- 1 January 1983
- journal article
- Published by Taylor & Francis in Acta Radiologica: Oncology
- Vol. 22 (4) , 331-336
- https://doi.org/10.3109/02841868309134049
Abstract
After reviewing the method of Hall et coll. (1966) for calculating dose rates from 192Ir wire, small changes and improvements were made and a computer program was written to calculate dose distributions. It was found that the wire position data obtained from films and supplied to the program was the largest source of inaccuracy but that with care the maximum error in the calculated dose rates was 3 per cent. If the original cross-line curves are still used for calculations the additional error introduced into the dose rates at distances of up to 4 cm from the wire is less than one per cent.Keywords
This publication has 3 references indexed in Scilit:
- Radiotherapy planning of inclined lesionsThe British Journal of Radiology, 1979
- Photon cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100Atomic Data and Nuclear Data Tables, 1970
- The Effective Attenuation in Water of the Gamma Rays of Gold 198, Iridium 192, Cesium 137, Radium 226, and Cobalt 60Radiology, 1968