Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Spectrometry−Mass Spectrometry
- 19 May 1999
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 71 (13) , 2346-2357
- https://doi.org/10.1021/ac981380y
Abstract
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is a new technique that separates gas-phase ions at atmospheric pressure (760 Torr) and room temperature. A FAIMS instrument acts as an ion filter and can be set to continuously transmit one type of ion. Despite the stringent requirement for a flow of clean, dry gas in the FAIMS analyzer region, a method of coupling electrospray to FAIMS has been developed. The identity of the electrospray ions separated by FAIMS was determined using mass spectrometry (FAIMS-MS). The theory of FAIMS is discussed, and electrospray FAIMS-MS spectra of several compounds in modes P1, P2, N1, and N2 are presented. Ions appearing in P1 and N1 modes tend to have mobilities that increase as a function of increasing electric field strength, whereas ions appearing in P2 and N2 modes tend to have mobilities that decrease. In general, low-mass ions are focused in P1 and N1 modes, whereas larger ions (e.g., proteins) are focused in P2 and N2 modes. Short-chain peptides, (Gly)(n) where n = 1-6, are shown to cross over from P1 mode into P2 mode as the chain length increases. The removal of the low-mass solvent cluster ions, combined with a reduction of the background noise in electrospray FAIMS-MS, results in an improved signal-to-noise ratio for mass spectra of larger ions (e.g., cyctochrome c) when compared with conventional electrospray-MS. Preliminary results also suggest that various charge states of cytochrome c can be distinguished by FAIMS, implying that the ion mobility of these species at high electric field strength is sensitive to the structure of the protein ion. The linearity of response of electrospray FAIMS-MS was investigated using leucine enkephalin and shows the calibration curve to be linear for ∼3 orders of magnitude.Keywords
This publication has 19 references indexed in Scilit:
- High-order structure and dissociation of gaseous peptide aggregates that are hidden in mass spectraJournal of the American Society for Mass Spectrometry, 1998
- Quantitative Electrospray Mass Spectrometry of Halides and Halogenic AnionsJournal of Analytical Atomic Spectrometry, 1997
- Gas-Phase Conformation of Biological Molecules: BradykininJournal of the American Chemical Society, 1996
- An Experimentally Based Model of the Peroxidase-NADH Biochemical Oscillator: An Enzyme-Mediated Chemical SwitchJournal of the American Chemical Society, 1995
- Electrospray Ionization Ion Mobility SpectrometryAnalytical Chemistry, 1994
- A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric fieldInternational Journal of Mass Spectrometry and Ion Processes, 1993
- Principles and practice of electrospray ionization—mass spectrometry for large polypeptides and proteinsMass Spectrometry Reviews, 1991
- Some Developments in Nuclear Magnetic Resonance of SolidsScience, 1989
- Electrospray interface for liquid chromatographs and mass spectrometersAnalytical Chemistry, 1985
- Electrospray mass spectroscopy of macromolecules: Application of an ion-drift spectrometerJournal of Mass Spectrometry, 1984