Precision and Reproducibility of Measurements of Human Corneal Thickness with Rapid Optical Low-Coherence Reflectometry (OLCR)
- 1 January 1999
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 4 (1) , 152-6
- https://doi.org/10.1117/1.429901
Abstract
This study investigates the precision and intraindividual variability of a clinical optical pachometer based on low-coherence reflectometry, which was used to measure the central thickness of a human cornea in vivo. The instrument, attached to a slit lamp, is a single mode fiber optic based Michelson interferometer with a high repetition rate as previously described. The same operator performed ten sets of measurements on the same subject, each consisting of 20 consecutive scans, on each day for three consecutive days. By computing the means from every scan series, the thickness of the central cornea with optical pachometry was found to be 519.6±1.2 (range 518-521) μm on day 1, 519.9±0.9 (range 519-521) μm on day 2, and 523.8±0.6 (range 523-525) μm on day 3. The thickness values on day 3, where the subject suffered from a cold without clinical ocular involvement, were different from the two previous days (p<0.001, one way analysis of variance). Optical low-coherence reflectometry measurements of corneal thickness can be performed with high precision of about 1 μm and a high intra- and intersession reproducibility. © 1999 Society of Photo-Optical Instrumentation Engineers.Keywords
This publication has 15 references indexed in Scilit:
- Rapid and Precise In Vivo Measurement of Human Corneal Thickness with Optical Low-Coherence Reflectometry in Normal Human EyesJournal of Biomedical Optics, 1998
- Rapid and scalable scans at 21 m/s in optical low-coherence reflectometryOptics Letters, 1997
- Quantification of Stromal Thinning, Epithelial Thickness, and Corneal Haze after Photorefractive Keratectomy Using In Vivo Confocal MicroscopyOphthalmology, 1997
- Interferometric Measurement of Corneal Thickness With Micrometer PrecisionAmerican Journal of Ophthalmology, 1994
- Epithelial and Corneal Thickness Measurements by High-frequency Ultrasound Digital Signal ProcessingOphthalmology, 1994
- Micron‐resolution ranging of cornea anterior chamber by optical reflectometryLasers in Surgery and Medicine, 1991
- Variability of Ultrasonic PachometryOptometry and Vision Science, 1990
- THE THICKNESS OF THE HUMAN CORNEA AS DETERMINED BY A SPECULAR METHODActa Ophthalmologica, 1984
- ON THE OPTICAL MEASUREMENT OF CORNEAL THICKNESSActa Ophthalmologica, 1980
- Measurement of Corneal Thickness With the Haag-Streit PachometerArchives of Ophthalmology (1950), 1968