Measurement of impurities in a long-pulse, multiampere hydrogen beam
- 1 January 1981
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 52 (1) , 1-7
- https://doi.org/10.1063/1.1136439
Abstract
Impurity concentration in intense neutral beams extracted from both a 75 keV/6 A/10 s duoPIGatron ion source and a magnetic multipole line cusp ion source has been measured by magnetic deflection mass analyzer. After passage of 90% equilibrium neutralizer cell, the ion beam contains 1%–2% light impurities (such as C+, O+, H2O) and 0.02%–0.15% heavy impurities (such as Cu+, W+, Ag+). Taking into account the neutralization efficiency, the neutral beam is estimated to contain 3%–6% light impurities and 0.04%–0.3% heavy impurities. The impurities related to oxygen decrease with time during a 10 s pulse, while those related to carbon, copper, and tungsten increase slightly with time. The origin of these impurities is discussed and the source operation mode to reduce the impurity level is proposed for neutral beam injection.Keywords
This publication has 6 references indexed in Scilit:
- Quasi–dc extraction of 70 keV, 5 A ion beamReview of Scientific Instruments, 1980
- A convenient method for the measurement of species composition from an intense neutral beamReview of Scientific Instruments, 1979
- Analysis of particle species evolution in neutral-beam injection linesJournal of Applied Physics, 1979
- Evidence for neutral-beam-injected oxygen impurities in 2XIIBNuclear Fusion, 1979
- An experimental study on the stigmatic focusing condition of a magnetic sector mass analyzerNuclear Instruments and Methods, 1978
- Intense, mixed-energy hydrogen beams for CTR injectionNuclear Fusion, 1975