Slow magnetic domain wall motion
- 1 June 1977
- journal article
- research article
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 48 (6) , 2612-2617
- https://doi.org/10.1063/1.323984
Abstract
The speed u of slow magnetic domain wall motion has been measured as a function of applied field, H, over the interval 3.4×10−7⩽u⩽0.24 m/s at room temperature. It is found that speed does not vary exponentially with field although it may be approximated as such over restricted intervals. The data are analyzed both from the point of view of thermally activated motion and also quantum‐mechanical tunneling. It is found that the formalisms of these two cases are identical. They differ only in the definition of a characteristic distance l. It is concluded that thermal activation is more likely than tunneling to be the mechanism that is operative at room temperature.This publication has 14 references indexed in Scilit:
- Do ferromagnets have a true coercive force?Journal of Applied Physics, 1974
- Particle interactions in the thermal fluctuation aftereffect model of exchange anisotropyIEEE Transactions on Magnetics, 1974
- Possible tunneling in ferromagnetics with extraordinary viscosityPhysica Status Solidi (a), 1973
- Temperature and frequency dependence of exchange anisotropy effects in oxidized NiFe filmsJournal of Applied Physics, 1972
- Slow wall motion in oxidized permalloy filmsPhysica Status Solidi (a), 1972
- Autocorrelation Function of Barkhausen Noise in Simple MaterialsJournal of Applied Physics, 1972
- Investigation of the thermally activated wall movement in a wide range of temperatureIEEE Transactions on Magnetics, 1969
- Thermally Activated Ferromagnetic Domain Wall MotionAustralian Journal of Physics, 1960
- Magnetic Anisotropy of Dispersed PowdersAustralian Journal of Physics, 1960
- Slow Domain Wall Motion in Homogeneous Vacuum-Deposited Iron-Nickel FilmsJournal of Applied Physics, 1959