THROMBOSIS OF THE BJORK-SHILEY PROSTHESIS - ILLUSTRATIVE CASES AND REVIEW OF THE LITERATURE
- 1 January 1982
- journal article
- review article
- Vol. 84 (1) , 138-144
Abstract
Thrombosis of the Bjork-Shiley prosthetic cardiac valve may occur in any valve position and regardless of anticoagulant status. Four illustrative cases are presented to demonstrate management problems. Review of cases reported in the literature suggests the minimal incidence of thrombosis of Bjork-Shiley prostheses is about 2% in the aortic position and about 4% in the mitral position. Prevention of this complication appears to require continuous systemic anticoagulation with warfarin; even temporary interruption or alteration of anticoagulant regimen may be detrimental. Although changes in anticoagulation may rarely precipitate sudden thrombosis, in most cases a period averaging 10 mo. is required for pannus of organized thrombus to build up enough to cause acute thrombosis and valve malfunction. Operation to remove thrombus or replace the prosthesis is usually required for left-sided cardiac prostheses, but thrombosed valves in the tricuspid position may be successfully treated with fibrinolytic medical therapy.This publication has 14 references indexed in Scilit:
- Ten years’ experience with the Björk-Shiley tilting disc valveThe Journal of Thoracic and Cardiovascular Surgery, 1979
- Near fatal puerperal thrombosis on Bjork-Shiley mitral valve prosthesis.Heart, 1978
- The Björk-Shiley aortic prosthesis: flow characteristics, thrombus formation and tissue overgrowth.Circulation, 1978
- MISLEADING NONINVASIVE SIGNS OF BJORK-SHILEY MITRAL-VALVE DYSFUNCTION1978
- ACUTE THROMBOTIC OBSTRUCTION WITH BJORK-SHILEY VALVES - DIAGNOSTIC AND SURGICAL CONSIDERATIONS1978
- Ultrasonic evaluation of thrombosis of Björk-Shiley aortic valve prosthesisThe Journal of Thoracic and Cardiovascular Surgery, 1977
- RADIOPAQUE MARKER IN TILTING DISK OF BJORK-SHILEY HEART-VALVE - EVALUATION OF INVIVO PROSTHETIC VALVE FUNCTION BY CINE-RADIOGRAPHY1977
- Late Thrombosis of the Aortic Bjork-Shiley ProsthesisChest, 1976
- Echocardiographic Diagnosis of a Stuck Bjork-Shiley Aortic Valve ProsthesisChest, 1976
- Successful Replacement of a Thrombosed Björk-Shiley Mitral Valve ProsthesisJapanese Heart Journal, 1976