Long-Term Clinical Consequences of Stress-Shielding after Total Hip Arthroplasty without Cement*
- 1 July 1997
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 79 (7) , 1007-12
- https://doi.org/10.2106/00004623-199707000-00006
Abstract
Ip system. Three patients (three hips) died within ten years after the arthroplasty, leaving forty-four patients (forty-five hips) who had a minimum of ten years of clinical follow-up. At the time of the latest follow-up, thirty-eight patients (86 per cent) reported that they had either no or mild pain related to the hip, forty-two (95 per cent) had less pain than they had had preoperatively, and forty-one (93 per cent) were satisfied with the results of the arthroplasty.Two patients had a reoperation, but neither procedure involved the femoral component; specifically, one patient had a revision of a loose acetabular component and one had an exchange of a polyethylene liner. No femoral component was associated with clinical or radiographic evidence of loosening. Femoral osteolysis, confined to zones 1 and 7 of Gruen et al., was observed on the ten-year radiographs of four of the thirty-three hips for which such radiographs were available. Stress-shielding (defined as evidence of pronounced femoral bone-remodeling on the two-year radiographs) had not adversely affected the outcome for these four hips by the time of the latest follow-up.The findings regarding postoperative pain, function, and over-all satisfaction for the forty-four patients (forty-five hips) who were included in the present study were similar to those reported for our larger (parent) series of patients who had been managed with the anatomic medullary locking hip system and to those reported for a similar series of patients who were followed for 9.5 years after the insertion of a porous-coated anatomic prosthesis. In addition, the prevalence of acetabular and femoral osteolysis (four [12 per cent] of thirty-three hips) and that of revision of the femoral component (zero [0 per cent] of forty-five hips) were lower than those for our larger (parent) series (fifty-four [39 per cent] of 137 hips and three [1 per cent] of 201 hips, respectively) as well as those for the series of patients who had been managed with the porous-coated anatomic prosthesis (thirty-five [45 per cent] and four [5 per cent] of seventy-eight hips, respectively)....Keywords
This publication has 12 references indexed in Scilit:
- Long-Term Results of Use of the Anatomic Medullary Locking Prosthesis in Total Hip Arthroplasty*Journal of Bone and Joint Surgery, 1997
- Skeletal Response to Well Fixed Femoral Components Inserted With and Without CementClinical Orthopaedics and Related Research, 1996
- The Influence of Clinical Factors on Periprosthetic Bone RemodelingClinical Orthopaedics and Related Research, 1996
- Patterns of osteolysis around total hip components inserted with and without cement.Journal of Bone and Joint Surgery, 1995
- Dual-energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. Methods and preliminary resultsThe Journal of Bone and Joint Surgery. British volume, 1993
- Recent advances in cementless total hip arthroplasty using the AML prosthesisTechniques in Orthopaedics, 1991
- Quantifying bone loss from the proximal femur after total hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 1991
- The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic reviewThe Journal of Bone and Joint Surgery. British volume, 1990
- Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical resultsThe Journal of Bone and Joint Surgery. British volume, 1987
- THE LONG-TERM RESULTS OF LOW-FRICTION ARTHROPLASTY OF THE HIP PERFORMED AS A PRIMARY INTERVENTIONThe Journal of Bone and Joint Surgery. British volume, 1972