Comparison of Hallway and Treadmill Six-minute Walk Tests
- 1 November 1999
- journal article
- clinical trial
- Published by American Thoracic Society in American Journal of Respiratory and Critical Care Medicine
- Vol. 160 (5) , 1540-1543
- https://doi.org/10.1164/ajrccm.160.5.9808139
Abstract
The 6-min walk test (SMWT) performed in the hallway (HW) is used as a clinical indicator of functional capacity in patients with lung disease. A 6-min walk test utilizing a treadmill (TM) is easier to perform and allows easier patient monitoring. Therefore, we formulated a standardized TM SMWT protocol and compared the results with those of a HW SMWT. All patients were enrolled in a pulmonary rehabilitation program. Patients with current infection, recent change in inhaled medications or oral steroid use, and significant cardiovascular disease were excluded. Each subject performed three HW SMWTs and three TM SMWTs assigned randomly on subsequent days. There was a 30-min rest between each walk and at least a 48-h rest between each test day. All patients completed both HW and TM SMWT within 7 d. Supplemental oxygen was utilized or increased if the saturation fell below 88%. The best of the three tests was used for data analysis. Twenty-one subjects completed the protocol. The mean age was 65 +/- 10.9 yr (range, 35 to 79 yr). Ten subjects were receiving supplemental oxygen. The mean FEV(1) was 1.07 +/- 0.53 L. The mean HW SMWT distance was 1,228 +/- 255 ft (range, 612 to 1,679 ft) and the mean TM SMWT distance was 1,060 +/- 389 ft (range, 475 to 1,819 ft), which were statistically different (p = 0.01). The mean difference was 168 +/- 280 ft (range, -326 to 743 ft). Oxygen saturation and supplemental oxygen requirements did not differ significantly. The intra-test variability of the three HW SMWTs was similar to the three TM SMWTs and no significant difference in the coefficient of variation was found. A standardized TM SMWT is feasible and allows easier patient monitoring, but there is a statistically significant difference between the HW and TM SMWT distance and therefore they are not interchangeable. However, the intratest reproducibility of the TM and HW SMWTs are similar when three walks are performed in a single test session. The role of the TM SMWT in pulmonary rehabilitation requires further exploration.Keywords
This publication has 14 references indexed in Scilit:
- Interpreting small differences in functional status: the Six Minute Walk test in chronic lung disease patients.American Journal of Respiratory and Critical Care Medicine, 1997
- Results of 150 consecutive bilateral lung volume reduction procedures in patients with severe emphysemaThe Journal of Thoracic and Cardiovascular Surgery, 1996
- Development of a shuttle walking test of disability in patients with chronic airways obstruction.Thorax, 1992
- Long-Term Functional Follow-up of Lung Transplant RecipientsClinics in Chest Medicine, 1990
- A simple and portable paced step test for reproducible measurements of ventilation and oxygen consumption during exercise.Thorax, 1987
- A self paced treadmill walking test for breathless patients.Thorax, 1985
- Effect of encouragement on walking test performance.Thorax, 1984
- Two-, six-, and 12-minute walking tests in respiratory disease.BMJ, 1982
- Dyspnoea, disability, and distance walked: comparison of estimates of exercise performance in respiratory disease.BMJ, 1978
- Twelve-minute walking test for assessing disability in chronic bronchitis.BMJ, 1976