Pressure and flow waves in systemic arteries and the anatomical design of the arterial system.
- 1 August 1967
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 23 (2) , 139-149
- https://doi.org/10.1152/jappl.1967.23.2.139
Abstract
Pressure and flow waves were recorded in systemic arteries of 50 anesthetized dogs and 2 anesthetized wombats under control conditions and during occlusion of peripheral arteries. Flow was measured with electromagnetic flow-meters and pressure with Statham and Sanborn manometers. Pressure/ flow relationships were expressed as vascular impedance. The principal changes in contour and harmonic content of the waves between the heart and peripheral arteries were explained on the basis of wave reflection from 2 functionally discrete sites[long dash]1 close to the heart and representing the resultant of arterial terminations in the head, neck, and upper limbs, and the other further from the heart and representing the resultant of arterial terminations in the trunk and lower limbs. Peripheral reflection coefficients depend on the spatial dispersion of arterial terminations (and so, body shape) as well as on arteriolar tone. Differences in body shape explain in part the different pressure and flow patterns in corresponding arteries of different mammals. The concept of arterial "standing waves" was re-examined; criticism of this concept was affirmed.This publication has 13 references indexed in Scilit:
- Vascular Impedance of the Femoral BedCirculation Research, 1966
- The Input Impedance of an Assembly of Randomly Branching Elastic TubesBiophysical Journal, 1966
- Pressure-flow relationships in the ascending aorta and femoral artery of manJournal of Applied Physiology, 1965
- Dynamic accuracy of the electromagnetic flowmeterJournal of Applied Physiology, 1965
- Single-Coil Coreless Electromagnetic Blood-Flow MetersIEEE Transactions on Biomedical Engineering, 1963
- Pulse contour changes in carotid and foreleg arterial systemsAmerican Journal of Physiology-Legacy Content, 1962
- MINIATURIZATION OF THE ELECTROMAGNETIC BLOOD FLOW METER AND ITS USE FOR THE RECORDING OF CIRCULATORY RESPONSES OF CONSCIOUS ANIMALS TO SENSORY STIMULIProceedings of the National Academy of Sciences, 1959
- Formation of Peripheral Pulse Contour in ManJournal of Applied Physiology, 1956
- THE PATTERNS OF THE ARTERIAL PRESSURE PULSEAmerican Journal of Physiology-Legacy Content, 1944
- AN EXPERIMENTAL STUDY OF THE STANDING WAVES IN THE PULSE PROPAGATED THROUGH THE AORTAAmerican Journal of Physiology-Legacy Content, 1938