Background: Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX).Methods: A total of 71 subjects (6–60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD).Results: Success rate was high (≥ 84%) in both devices for both adults and children. The subjects represented a FENOrange of 8–147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively.Conclusion: The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children. The new hand-held device will enable the introduction of exhaled NO measurements into the primary health care.Keywords
This publication has 16 references indexed in Scilit:
- Titrating Steroids on Exhaled Nitric Oxide in Children with AsthmaAmerican Journal of Respiratory and Critical Care Medicine, 2005
- ATS/ERS Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal Nitric Oxide, 2005American Journal of Respiratory and Critical Care Medicine, 2005
- The Aerocrine exhaled nitric oxide monitoring system NIOX is cleared by the US Food and Drug Administration for monitoring therapy in asthmaJournal of Allergy and Clinical Immunology, 2004
- Diagnosing AsthmaAmerican Journal of Respiratory and Critical Care Medicine, 2004
- Prospective Evaluation of the Validity of Exhaled Nitric Oxide for the Diagnosis of AsthmaaChest, 2003
- Airway Inflammation Is Present during Clinical Remission of Atopic AsthmaAmerican Journal of Respiratory and Critical Care Medicine, 2001
- Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal Nitric Oxide in Adults and Children—1999American Journal of Respiratory and Critical Care Medicine, 1999
- Correlation between exhaled nitric oxide, sputum eosinophils, and methacholine responsiveness in patients with mild asthma.Thorax, 1998
- Endogenous nitric oxide is present in the exhaled air of rabbits, guinea pigs and humansBiochemical and Biophysical Research Communications, 1991
- Homogeneous chemiluminescent measurement of nitric oxide with ozone. Implications for continuous selective monitoring of gaseous air pollutantsAnalytical Chemistry, 1970