Heparin-Coated Palmaz-Schatz Stents in Human Coronary Arteries
- 1 February 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 93 (3) , 412-422
- https://doi.org/10.1161/01.cir.93.3.412
Abstract
Background The purpose of the Benestent-II Pilot Study was to evaluate the safety of delaying and eliminating anticoagulant therapy in patients receiving a heparin-coated stent in conjunction with antiplatelet drugs. Methods and Results The study consisted of three initial phases (I, II, III) during which resumption of heparin therapy after sheath removal was progressively deferred by 6, 12, and 36 hours. In phase IV, coumadin and heparin were replaced by 250 mg ticlopidine and 100 mg aspirin. Of the 207 patients with stable angina pectoris and a de novo lesion in whom heparin-coated stent implantation was attempted, implantation was successful in 202 patients (98%). Stent thrombosis did not occur during all four phases, and the overall clinical success rate at discharge was 99%. Bleeding complications requiring blood transfusion or surgery fell from 7.9% in phase I to 5.9%, 4%, and 0% in the three following phases. Hospital stay was 7.4, 6.1, 7.2, and 3.1 days for the consecutive phases. The restenosis rate for the combined four phases was 13% (15% in phase I, 20% in phase II, 11% in phase III, and 6% in phase IV). The overall rate of reintervention for the four phases was 8.9%. At 6 months, 84%, 75%, 94%, and 92% of the patients of phases I to IV, respectively, were event free. For the four phases, the event-free rate was 86%, which compares favorably with the rate observed in the Benestent-I study (80%; relative risk, 0.68 [0.45 to 1.04]). Conclusions The implantation of stents coated with polyamine and end-point–attached heparin in stable patients with one significant de novo coronary lesion is well tolerated, is associated with no (sub)acute stent thrombosis, and results in a favorable event-free survival after 6 months.Keywords
This publication has 30 references indexed in Scilit:
- Benestent II: Back to the FutureJournal of Interventional Cardiology, 1994
- Attenuation of hypertensive-induced pulsus alternans by nifedipine and nitroglycerinCatheterization and Cardiovascular Diagnosis, 1994
- Modification of the Thrombogenicity of a Self-Expanding Vascular StentJournal of Investigative Surgery, 1991
- Surface tension effects of heparin coating on arterial line filtersPerfusion, 1990
- The Search for Thromboresistance Using Immobilized HeparinAnnals of the New York Academy of Sciences, 1987
- Heparinlike molecules with anticoagulant activity are synthesized by cultured endothelial cellsBiochemical and Biophysical Research Communications, 1985
- A canine ex vivo series shunt for evaluating thrombus deposition on polymer surfacesJournal of Biomedical Materials Research, 1984
- Effect of Heparin and Heparin Fractions on Platelet AggregationJournal of Clinical Investigation, 1980
- A new antithrombogenic heparinized polymerJournal of Biomedical Materials Research, 1977
- COVALENT BINDING OF BIOMOLECULES TO RADIATION-GRAFTED HYDROGELS ON INERT POLYMER SURFACESAsaio Journal, 1972