Cardiac Output Measurement by Thermal Dilution
- 1 January 1976
- journal article
- research article
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 183 (1) , 67-72
- https://doi.org/10.1097/00000658-197601000-00014
Abstract
Cardiac output estimates by the principle of thermodilution (COth) was compared with dye-dilution estimates (COdye) in pigs. For COth estimates a Swan-Ganz 7 F floating thermodilution catheter and a 9500 Edwards Computer, were used. The COdye estimates were obtained by the apparatus constructed by Zijlstra and Mook. The effect of the thermistor position in the pulmonary artery on the COth estimates was also investigated. The reproducibility of COth was examined by duplicate determinations. Based on 101 simultaneous estimates of COth and COdye the correlation was found COth = 1.020 COdye + 0.2378, r = 0.971 for cardiac outputs between 0.65 l/min and 11 l/min. For 111 duplicate determinations of COth between 2 and 9 l/min the coefficient of variation was 4.74%. The thermistor position in the pulmonary artery had no influence on the COth estimates provided an undamped pressure curve could be monitored from the tip of the catheter. Cardiac output can thus be measured rapidly with good accuracy also for low values by means of a blindly inserted thermistor catheter positioned without x-ray control and a computer with digital display.Keywords
This publication has 12 references indexed in Scilit:
- The dye-dilution technique fof measurement or cardiac output during operation for valvular disease: the importance of injection site.1975
- Validity of thermodilution method for measurement of cardiac output in pulmonary oedemaCardiovascular Research, 1973
- Thermodilution cardiac output determination with a single flow-directed catheterAmerican Heart Journal, 1972
- A new technique for measurement of cardiac output by thermodilution in manThe American Journal of Cardiology, 1971
- Validity and Reproducibility of Determination of Cardiac Output by Thermodilution in ManCardiology, 1970
- A Computer as an Aid in Calculating Cardiac OutputScandinavian Journal of Clinical and Laboratory Investigation, 1967
- Calculation of Cardiac Output from Indicator-Dilution Curves in the Presence of Mitral RegurgitationCirculation, 1965
- Cardiac output measured by thermal dilution of room temperature injectateJournal of Applied Physiology, 1961
- The value of injections of dye into the left heart in the study of mitral and aortic valvular disease by catheterization of the left heartAmerican Heart Journal, 1960
- THE RELIABILITY OF THE THERMODILUTION METHOD FOR DETERMINATION OF THE CARDIAC OUTPUT AND THE BLOOD FLOW IN CENTRAL VEINSQuarterly Journal of Experimental Physiology and Cognate Medical Sciences, 1957