Heparin–coated circuit during cardiopulmonary bypass
- 1 May 1994
- journal article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 38 (4) , 372-379
- https://doi.org/10.1111/j.1399-6576.1994.tb03910.x
Abstract
A prospective randomized study was performed to investigate the effect of surface coating with covalently endpoint-attached heparin (Carmeda Bio Active Surface) and reduced general heparinization on haematological indices and complement C5 activation. Care was taken to optimize the rheological design of the system using centrifugal pump and a closed system without venting or machine suction. Twenty patients scheduled for aortocoronary bypass grafting (EF > 0.5) participated in the study. Ten patients were randomized to be treated with heparin-coated equipment (CBAS) and reduced i.v. heparin (1.5 mg.kg-1) while 10 patients treated with identical but noncoated equipment and full heparinization (3 mg.kg-1) served in a Control group. A vacuum suction was used to collect the blood from the operating field and it was autotransfused at weaning from extracorporeal circulation (ECC). Blood samples were obtained from the venous (precircuit) and arterial (postcircuit) side. We used a new and very specific method for detection of C5a based on monoclonal antibodies. The concentration of C5a was low in both groups during the operation but a significant increase was seen on days 1 and 2. In the Control group there was an increase from 10.2 ng.ml-1 +/- 1.2 to 27.5 ng.ml-1 +/- 4.8 on day 2 and in the CBAS group from 10.7 ng.ml-1 +/- 1.2 to 35.6 ng.ml-1 +/- 11.6 on day 2 (NS between groups). The granulocytes and total leukocyte count increased at the end of ECC and was maintained at the elevated level throughout the study period. The amount of free haemoglobin was high in the autotransfused blood in both groups.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 19 references indexed in Scilit:
- Does Choice of Anesthetic Agent Significantly Affect Outcome after Coronary Artery Surgery?Anesthesiology, 1989
- Deposition of Terminal C5b–9 Complement Complexes on Erythrocytes and Leukocytes during Cardiopulmonary BypassNew England Journal of Medicine, 1988
- Extracorporeal Elimination of Carbon Dioxide Using a Surface-Heparinized Veno-Venous Bypass SystemAnnual Northeast Bioengineering Conference, 1986
- Cardiopulmonary effects of cuprophane–activated plasma in the swineKidney International, 1986
- Effects of Protamine Administration after Cardiopulmonary Bypass on Complement, Blood Elements, and the Hemodynamic StateThe Annals of Thoracic Surgery, 1986
- Phospholipase A Activation Following Extracorporeal Circulation and its Blockade by ProcaineThe Thoracic and Cardiovascular Surgeon, 1983
- A New Non-Thrombogenic Surface Prepared by Selective Covalent Binding of Heparin Via a Modified Reducing Terminal ResidueBiomaterials, Medical Devices, and Artificial Organs, 1983
- Complement Activation during Cardiopulmonary BypassNew England Journal of Medicine, 1981
- Importance of Free Fatty Acids as a Determinant of Myocardial Oxygen Consumption and Myocardial Ischemic Injury during Norepinephrine Infusion in DogsJournal of Clinical Investigation, 1974
- Anaphylatoxin inactivator of human plasma: its isolation and characterization as a carboxypeptidaseJournal of Clinical Investigation, 1970