Serum ferritin assay and iron status in chronic renal failure and haemodialysis.
- 8 March 1975
- Vol. 1 (5957) , 546-548
- https://doi.org/10.1136/bmj.1.5957.546
Abstract
Forty-four patients with chronic renal failure on haemodialysis for four months to eight years were studied. All recieved intravenous iron dextran 100 mg on alternate weeks. Serum ferritin concentrations correlated well with body iron stores estimated by grading the bone marrow stainable iron. Altogether 34 patients showed increased bone marrow iron stores and serum ferritin concentrations greater than controls; four patients showed absence of iron in the marrow, and three of these had subnormal serum ferritin concentrations. Serum ferritin assay represents the best method of repeatedly monitoring the exact amount of iron therapy needed by patients with chronic renal failure, particularly those on regular haemodialysis.Keywords
This publication has 7 references indexed in Scilit:
- Serum ferritin concentration and iron stores in normal subjectsJournal of Clinical Pathology, 1973
- Ferritin in the Serum of Normal Subjects and Patients with Iron Deficiency and Iron OverloadBMJ, 1972
- An immunoradiometric assay for ferritin in the serum of normal subjects and patients with iron deficiency and iron overloadJournal of Clinical Pathology, 1972
- Iron Metabolism in Patients Undergoing Regular Dialysis TherapyBMJ, 1971
- IRON THERAPY IN PATIENTS ON MAINTENANCE HqMODIALYSISThe Lancet, 1970
- Iron Absorption in Chronic Renal DiseaseClinical Science, 1970