Experimental atrial septal defect closure with a new, transcatheter, self-centering device.
- 1 October 1993
- journal article
- abstracts
- Published by Wolters Kluwer Health in Circulation
- Vol. 88 (4) , 1754-1764
- https://doi.org/10.1161/01.cir.88.4.1754
Abstract
BACKGROUND Despite two decades of research, a transcatheter atrial septal defect closure device is not available for clinical use. We have designed a new superelastic Nitinol-Dacron, double-disk, self-centering, atrial septal defect closure device and studied its efficacy in a canine model of atrial septal defects. METHODS AND RESULTS Atrial septal defects were created surgically in 20 adult dogs using either a 7.5-mm or 10-mm punch. Percutaneous transcatheter closures were attempted using a new device. The device sizes used were 20 mm in 6 dogs, 22 mm in 9, and 25 mm in 5 (22.1 +/- 1.9 mm, mean +/- SD). The stretched atrial septal defect diameter was 10.5 +/- 1.3 mm, and the device to stretched atrial septal defect diameter ratio was 2.1 +/- 0.3. Closures were successful in 19 studies and unsuccessful in 1. Angiography showed a left-to-right shunt in all 20 dogs before closure. Immediately after closure (n = 19), there were no shunts in 17 and trivial shunts in 2. Six dogs were followed for a period of 4.7 +/- 3.0 months (range, 2 to 8 months). The trivial shunt present in 1 animal immediately after closure had closed by the time of the repeat study. Spontaneous embolization of the device was not seen during follow-up. A solitary wire fracture was found 8 months after closure in 1 device. Light microscopy at 8 weeks in 3 dogs showed the devices to be covered by smooth endocardium, enmeshed in mature collagen tissue, with a minimal mononuclear cell infiltration. Retrievability was assessed by deliberately embolizing 4 devices in 2 dogs into the right atrium (n = 1) and pulmonary artery (n = 3). All devices were successfully retrieved with a snare. CONCLUSIONS This feasibility study demonstrates that this new self-centering atrial septal defect closure device has a number of design features that permit effective and safe closures in a canine model. These results support the investigation of this device in human clinical trials.Keywords
This publication has 13 references indexed in Scilit:
- Catheter closure of atrial septal defect: Successful use in a 3.6 kg infantAmerican Heart Journal, 1991
- Transvenous atrial septal defect occlusion by the buttoned deviceThe American Journal of Cardiology, 1990
- Simon nitinol inferior vena cava filter: initial clinical experience. Work in progress.Radiology, 1989
- Local Intravascular Effects of the Nitinol Wire Blood Clot FilterInvestigative Radiology, 1988
- Interventional cardiac catheterization in congenital heart diseaseInternational Journal of Cardiology, 1985
- Nonsurgical placement of arterial endoprostheses: a new technique using nitinol wire.Radiology, 1983
- Transluminal expandable nitinol coil stent grafting: preliminary report.Radiology, 1983
- Biocompatibility of nitinol alloy as an implant materialJournal of Biomedical Materials Research, 1976
- Secundum Atrial Septal DefectJAMA, 1976
- Technic for production of experimental ventricular septal defectsThe American Journal of Surgery, 1966