Highly accurate coronary angiography with submillimetre, 16 slice computed tomography
Open Access
- 1 March 2005
- Vol. 91 (3) , 308-313
- https://doi.org/10.1136/hrt.2004.034892
Abstract
Objective: To assess submillimetre coronary computed tomographic angiography (CTA) in comparison with invasive quantitative coronary angiography as the gold standard and to examine the effect of significant coronary artery calcification (CAC), which is known to impede lumen visualisation, on the accuracy of the examination. Methods: After invasive coronary angiography, 58 patients underwent coronary imaging with a GE Lightspeed 16 computed tomography (CT) system. CAC was quantified after an ECG triggered acquisition with a low tube current. Coronary CTA was performed with retrospective ECG gating and a 16 × 0.63 mm collimation and was reconstructed with an effective 65–250 ms temporal resolution. All 13 major coronary artery segments were evaluated for the presence of ⩾ 50% stenosis, and compared with the gold standard. Results: One patient moved and could not be evaluated. All segments (except occluded segments) were evaluated for 57 patients. Overall the accuracy of coronary CTA for detection of ⩾ 50% stenosis was: sensitivity 83%, specificity 97%, positive predictive value 80%, and negative predictive value 97%. The number of diseased coronary arteries was correctly diagnosed in 34 of 38 (89%) patients overall. Altogether 21 of 57 (37%) patients had a CAC score ⩾ 400, which was predefined as representing significant CAC. Excluding these patients from the analysis improved the accuracy of coronary CTA to a sensitivity of 89%, specificity 98%, positive predictive value 79%, and negative predictive value 99%. Conclusions: Non-invasive coronary angiography with submillimetre CT is reliable and accurate. It appears that a subgroup of patients may be selected based on CAC score in whom the investigation has even higher accuracy. Coronary CTA has reached the stage where it should be considered for a clinical role. Further research is required to define this role.Keywords
This publication has 14 references indexed in Scilit:
- Multislice Computed Tomographic Coronary Angiography: Experience in a UK CentreClinical Radiology, 2003
- Advances in Cardiac Imaging with 16-Section CT SystemsAcademic Radiology, 2003
- Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patientsEuropean Heart Journal, 2002
- Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed TomographyCirculation, 2002
- Noninvasive Coronary Angiography Using Computed TomographyCirculation, 2002
- Darstellung der Herzkranzgefäße im CT mittels neuer 16-Zeilen-Technologie und reduzierter Rotationszeit: Erste ErfahrungenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulationEuropean Radiology, 2002
- Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenosesThe American Journal of Cardiology, 2001
- Coronary angiography with multi-slice computed tomographyThe Lancet, 2001
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975