CONSTRUCTION OF INEXPENSIVE, WALK-IN ENVIRONMENTAL CHAMBERS FOR STUDYING INSECT-TEMPERATURE RELATIONSHIPS1
- 1 July 1985
- journal article
- research article
- Published by Georgia Entomological Society in Journal of Entomological Science
- Vol. 20 (3) , 340-344
- https://doi.org/10.18474/0749-8004-20.3.340
Abstract
The construction of walk-in controlled environmental chambers that achieve high accuracy at low cost is described. These chambers are capable of maintaining air temperatures at 15 - 35° ± 0.5°C. Long term (weekly) humidity stability averages 75% RH at ±6%. The described units are useful for large-scale bioassay experiments.Keywords
This publication has 2 references indexed in Scilit:
- Inexpensive, Multiple-Unit Environmental Chambers with Temperature and Humidity Control1Annals of the Entomological Society of America, 1981
- A Device for Controlling Temperature and Relative Humidity in Small Chambers1Annals of the Entomological Society of America, 1966