High‐resolution variable flip angle 3D MR imaging of trabecular microstructure in vivo
- 1 April 1993
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 29 (4) , 528-539
- https://doi.org/10.1002/mrm.1910290415
Abstract
Two conceptually related variable‐flip‐angle 3D spin‐echo pulse sequences were designed for imaging at voxel sizes of 2–5 × 10−3 mm3 corresponding to pixel areas of less than 100 × 100 μm2 and section thicknesses on the order of 300–400 μm on a conventional 1.5 T MR imaging system equipped with 1 G/cm imaging field gradients, providing 12 sections in 10 min imaging time. The pulse sequences make use of the concept of restoring longitudinal magnetization inverted by the 180° phase reversal pulse and are derivatives of pulse sequences previously dubbed “FATE” and “RASEE.” It is shown that even in the small‐voxel regime (< 10−2 mm3 voxel size) and at echo times on the order of 10 ms, gradient echo images are sensitive to intrinsic fields causing artifactual boundary effects, including signal loss from intravoxel phase scrambling and spatial mismapping. At this resolution the variable flipangle spin‐echo pulse sequences are demonstrated to be better suited for imaging magnetically heterogeneous systems such as trabecular bone microstructure in vivo. These pulse sequences are found to be substantially less sensitive to distortions from magnetic dipole fields occurring at the boundaries of two phases of different magnetic permeability.Keywords
This publication has 26 references indexed in Scilit:
- Quantitation of the susceptibility difference between trabecular bone and bone marrow: Experimental studiesMagnetic Resonance in Medicine, 1991
- Quantitative study of the susceptibility difference between trabecular bone and bone marrow: Computer simulationsMagnetic Resonance in Medicine, 1991
- Optimal imaging strategies for three-dimensional nuclear magnetic resonance microscopyJournal of Magnetic Resonance (1969), 1991
- Fast-scan magnetic resonance-principles and applications. Felix W. Wehrli, PhD. New York: Raven Press, 1991. $45.00: pp 176: 91 figuresJournal of Magnetic Resonance Imaging, 1991
- In vivo Quantitative characterization of trabecular bone by NMRMagnetic Resonance in Medicine, 1991
- The direct examination of three-dimensional bone architecture in vitro by computed tomographyJournal of Bone and Mineral Research, 1989
- Potential problems with selective pulses in NMR imaging systemsMedical Physics, 1984
- Relationships between surface, volume, and thickness of iliac trabecular bone in aging and in osteoporosis. Implications for the microanatomic and cellular mechanisms of bone loss.Journal of Clinical Investigation, 1983
- The sensitivity of the zeugmatographic experiment involving human samplesJournal of Magnetic Resonance (1969), 1979
- Phase and intensity anomalies in fourier transform NMRJournal of Magnetic Resonance (1969), 1971