Transdiaphragmatic Pressure Control of Airway Pressure Support in Healthy Subjects
- 1 October 2003
- journal article
- research article
- Published by American Thoracic Society in American Journal of Respiratory and Critical Care Medicine
- Vol. 168 (7) , 760-769
- https://doi.org/10.1164/rccm.200203-241oc
Abstract
We designed a new servoventilator that proportionally adjusts airway pressure to transdiaphragmatic pressure (Pdi) generated by the subject during inspiration. Each cycle is triggered by either a preset Pdi increase or a preset inspiratory flow value (whichever is reached first), whereas cycling-off is flow-dependent. We evaluated the servoventilator in seven healthy subjects at normocapnia and three levels of hypercapnia (normocapnia + 3, + 6, and + 9 mm Hg) comparatively with spontaneous breathing. Triggering was by Pdi in six subjects and flow in one. At all end-tidal carbon dioxide pressure levels, time from onset of diaphragm electromyographic activity to inspiratory flow was similar with and without the servoventilator. Airway pressure increased proportionally to Pdi variation during servoventilator breathing. Flow, tidal volume, respiratory rate, intrinsic positive end-expiratory pressure, and esophageal and transdiaphragmatic pressure–time products increased significantly with hypercapnia with and without the servoventilator. Breathing pattern parameters were similar in the two breathing modes, and no differences were found for intrinsic positive end-expiratory pressure or gastric pressure variation during exhalation. Esophageal and transdiaphragmatic pressure–time products were lower with than without the servoventilator. The Pdi-driven servoventilator was well synchronized to the subjects effort, delivering a pressure proportional to Pdi and reducing respiratory effort at normocapnia and hypercapnia.Keywords
This publication has 39 references indexed in Scilit:
- Accuracy of end-tidal carbon dioxide monitoring using the NBP-75® microstream capnometer. A study in intubated ventilated and spontaneously breathing nonintubated patientsEuropean Journal of Anaesthesiology, 2000
- Non‐chemical inhibition of respiratory motor output during mechanical ventilation in sleeping humansThe Journal of Physiology, 1999
- Expiratory valves used for home devices: experimental and clinical comparisonEuropean Respiratory Journal, 1998
- Frequency and volume thresholds for inhibition of inspiratory motor output during mechanical ventilationRespiration Physiology, 1996
- Noninvasive Ventilation for Acute Exacerbations of Chronic Obstructive Pulmonary DiseaseNew England Journal of Medicine, 1995
- Effects of inspiratory support upon breathing in humans during wakefulness and sleepRespiration Physiology, 1993
- Frequency of mechanical ventilation and respiratory activity after double lung transplantationRespiration Physiology, 1993
- Inhibition of respiratory activity during passive ventilation: a role for intercostal afferents?Respiration Physiology, 1993
- Effects of volume and frequency of mechanical ventilation on respiratory activity in humansRespiration Physiology, 1986
- Blood/gas equilibrium of carbon dioxide in lungs. A critical reviewRespiration Physiology, 1980