Intraoperative 3D imaging of the facial skeleton using the SIREMOBIL Iso-C3D
- 1 March 2004
- journal article
- case report
- Published by Oxford University Press (OUP) in Dento maxillo facial radiology
- Vol. 33 (2) , 130-132
- https://doi.org/10.1259/dmfr/15309653
Abstract
With respect to high-contrast structures, cone beam computed tomography (CBCT) offers an alternative imaging modality to computed tomography (CT), requiring less radiation exposure. The C-arm system SIREMOBIL Iso-C3D for three-dimensional (3D) reconstruction has made this modality available for intraoperative use. This paper presents the first intraoperative images of the facial skeleton using the SIREMOBIL Iso-C3D. Cases of a zygomaticomaxillary complex fracture, a mandibular angle fracture and a bimaxillary repositioning osteotomy are described to demonstrate the application possibilities of this system in maxillofacial surgery. In addition to the uncomplicated handling of the SIREMOBIL Iso-C3D, generally important was the low level of metal artefacts in its primary and secondary reconstructions, even in close proximity to the material. However, it has to be kept in mind that while soft tissues are visualized using CBCT, information about soft tissue quality cannot be obtained. The SIREMOBIL Iso-C3D generates intraoperative data sets suitable for the visualization of the facial bones after open reduction of fractures.Keywords
This publication has 13 references indexed in Scilit:
- Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiographyDento maxillo facial radiology, 2004
- 3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil Iso-C3D)Dento maxillo facial radiology, 2003
- Möglichkeiten der intraoperativen Diagnostik mit einem fahrbaren ComputertomographenMund-,Kiefer- und Gesichtschirurgie, 2002
- Three-dimensional CT with a Modified C-Arm Image Intensifier: FeasibilityRadiology, 2002
- Clinical indications for digital volume tomography in oral and maxillofacial surgery.Dento maxillo facial radiology, 2002
- Frakturdiagnostik am Kniegelenk mit einem neuen mobilen CT-System (ISO-C-3D): Vergleich mit konventionellem Röntgen und Spiral-CTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Use of Intraoperative Computed Tomography During Repair of Orbitozygomatic FracturesArchives of Facial Plastic Surgery, 1999
- Computed Tomography Use and Repair of Orbitozygomatic FracturesArchives of Facial Plastic Surgery, 1999
- Analysis of treatment for isolated zygomaticomaxillary complex fracturesJournal of Oral and Maxillofacial Surgery, 1996
- Toward CT-Based Facial Fracture TreatmentPlastic and Reconstructive Surgery, 1990