The wrist flexion test of Phalen has been studied in 127 patients with carpal tunnel syndrome and 20 control subjects, all of whom also had nerve conduction studies. There was a statistically significant relationship between the severity of electrical changes and the probability of a positive Phalen’s test. However 34% of patients had a negative test and 20% of control subjects a positive one.