A spark gap switching system for gasdynamic facilities
- 1 November 1974
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 45 (11) , 1397-1399
- https://doi.org/10.1063/1.1686511
Abstract
A spark gap switching system has been developed to coordinate the discharge of a 300 kJ capacitor bank with the high speed flow of helium in a shock tube driver. The trigger system includes a flow transducer, a pulse forming circuit, a high voltage sparkgenerator, and four heavy duty spark gaps that can carry total peak currents greater than 1.5×106 A. A glow gauge flow transducer sensitive to small gas density changes was used whose input power and signal output can withstand high voltage fluctuations. This switching system is of use with gasdynamicdischarge devices requiring a minimum number of switches.Keywords
This publication has 3 references indexed in Scilit:
- A conical arc driver for high-energy test facilities.AIAA Journal, 1972
- A higher performance electric-arc-driven shock tubeAIAA Journal, 1971
- Scyllacita—Compact High Voltage Theta Pinch MachineReview of Scientific Instruments, 1966