Mechanical Prevention of Distal Embolization During Primary Angioplasty
- 15 July 2003
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 108 (2) , 171-176
- https://doi.org/10.1161/01.cir.0000079223.47421.78
Abstract
Effective myocardial reperfusion after primary percutaneous coronary intervention (PCI) may be limited by distal embolization. We tested the safety, feasibility, and efficacy of the FilterWire-Ex (FW), a distal embolic protection device, as an adjunct to primary PCI. Fifty-three consecutive patients undergoing primary PCI with FW protection were compared with a matched control group treated by primary PCI alone. Successful FW positioning was obtained in 47 patients (89%) without complications. Histological analysis of the content of the last 13 filters showed multiple embolic debris in all cases. FW use was associated with lower postinterventional corrected TIMI frame count (22+/-14 versus 31+/-19; P=0.005) and higher occurrence of grade 3 myocardial blush (66% versus 36%; P=0.006) and early ST-segment elevation resolution (80% versus 54%; P=0.006). At multivariate analysis, FW use was the only independent predictor of early ST-segment elevation resolution and of grade 3 myocardial blush. FW patients showed lower peak creatine kinase-MB release (236+/-172 versus 333+/-219 ng/mL; P=0.013) and greater improvement at 30 days in left ventricular wall motion score index (-0.30+/-0.19 versus -0.18+/-0.26; P=0.008) and ejection fraction (+7+/-4% versus +4+/-7%; P=0.012). FW use during primary PCI is feasible and safe. Distal embolization prevention appears to exert a beneficial effect on markers of myocardial reperfusion and on left ventricular function improvement at 30 days.Keywords
This publication has 16 references indexed in Scilit:
- Angiographic Morphologic Features of Infarct-Related Arteries and Timely Reperfusion in Acute Myocardial InfarctionChest, 2002
- Initial clinical experience with distal protection using the FilterWire in patients undergoing coronary artery and saphenous vein graft percutaneous interventionCatheterization and Cardiovascular Interventions, 2002
- Integrated Analysis of Myocardial Blush and ST-Segment Elevation Recovery After Successful Primary AngioplastyCirculation, 2002
- Incidence and clinical significance of distal embolization during primary angioplasty for acute myocardial infarctionEuropean Heart Journal, 2002
- Intracoronary Thrombectomy With the X-Sizer Catheter System Improves Epicardial Flow and Accelerates ST-Segment Resolution in Patients With Acute Coronary SyndromeCirculation, 2002
- Comparison of Angioplasty with Stenting, with or without Abciximab, in Acute Myocardial InfarctionNew England Journal of Medicine, 2002
- The coronary no-reflow phenomenon: a review of mechanisms and therapiesEuropean Heart Journal, 2001
- Long-Term Benefit of Primary Angioplasty as Compared with Thrombolytic Therapy for Acute Myocardial InfarctionNew England Journal of Medicine, 1999
- Coronary embolization after balloon angioplasty or thromolytic therapy: An autopsy study of 32 casesJournal of the American College of Cardiology, 1993
- The Thrombolysis in Myocardial Infarction (TIMI) TrialNew England Journal of Medicine, 1985