Ocular Component Measurement Using the Zeiss IOLMaster
- 1 January 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Optometry and Vision Science
- Vol. 81 (1) , 27-34
- https://doi.org/10.1097/00006324-200401000-00007
Abstract
Axial length is traditionally measured using A-scan ultrasound. The IOLMaster is a new instrument that uses partial coherence interferometry to measure axial length. We compared the repeatability of these techniques for both an experienced and an inexperienced observer, the agreement between the two techniques, and the effect of cycloplegia on IOLMaster measurements. Five measurements of axial length and three measurements of anterior chamber depth were taken with the IOLMaster in two sessions separated by 1 to 12 days in 20 young adults. The two examiners each took measurements, and the subject was then cyclopleged with 1% tropicamide. The IOLMaster readings were then repeated by both examiners, followed by five ultrasound readings. Repeatability was evaluated by calculating the difference between measurements from the two sessions. The mean and standard deviation of these differences was then used to determine the 95% limits of agreement (LoA) for each technique. In addition, the agreement between the IOLMaster and ultrasound was assessed, along with the effect of cycloplegia on IOLMaster readings. The IOLMaster was more repeatable than ultrasound. For axial length, the 95% LoA were −0.11 to +0.07 mm, −0.06 to +0.05 mm, and −0.25 to +0.35 mm, for noncycloplegic IOLMaster, cycloplegic IOLMaster, and ultrasound, respectively. The two instruments showed modest agreement with each other (mean difference, +0.12 mm; 95% LoA, −0.39 to +0.64 mm; p > 0.0125). Cycloplegia had no significant effect on IOLMaster axial length measurements. The 95% LoA for anterior chamber depth measurement were −0.11 to +0.18 mm, −0.06 to +0.04 mm, and −0.19 to +0.21 mm, for noncycloplegic IOLMaster, cycloplegic IOLMaster, and ultrasound, respectively. The IOLMaster gave significantly longer anterior chamber depths than ultrasound (mean, +0.18 mm; 95% LoA, −0.02 to +0.37 mm; p < 0.0125), and cycloplegia produced significantly deeper anterior chamber depths using the IOLMaster (mean, +0.12 ± 0.09 mm; 95% LoA, −0.05 to +0.29 mm; t = 6.17; p < 0.001). The experienced observer’s measurements were more repeatable than the inexperienced observer’s for ultrasound, but not for the IOLMaster. The superior repeatability of the IOLMaster suggests that it should become the standard for axial length measurement. The 95% limits of agreement for the cycloplegic measurements correspond to a change in refractive error of ±0.12 D.Keywords
This publication has 19 references indexed in Scilit:
- A new non-contact optical device for ocular biometryBritish Journal of Ophthalmology, 2002
- Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliabilityJournal of Cataract & Refractive Surgery, 2001
- The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster™*Ophthalmic and Physiological Optics, 2001
- The Contact Lens and Myopia Progression (CLAMP) Study: Design and Baseline DataOptometry and Vision Science, 2001
- Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to HaigisAlbrecht von Graefes Archiv für Ophthalmologie, 2000
- A Randomized Trial of the Effect of Single-Vision vs. Bifocal Lenses on Myopia Progression in Children with EsophoriaOptometry and Vision Science, 2000
- Partial coherence interferometry: a novel approach to biometry in cataract surgeryPublished by Elsevier ,1998
- Initial Cross-Sectional Results from the Orinda Longitudinal Study of MyopiaOptometry and Vision Science, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Unified Model for Accommodative MechanismAmerican Journal of Ophthalmology, 1970