The effect of six reaction media on the determination of bismuth at trace levels in environmental samples by hydride generation and inductively coupled plasma-atomic emission spectrometry
- 1 January 1999
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 14 (12) , 1875-1881
- https://doi.org/10.1039/a906599g
Abstract
An investigation was carried out to explore the effect of hydrochloric, tartaric, citric, oxalic, acetic and sulfosalicylic acids on the hydride generation of Bi at trace levels in a continuous flow system in conjunction with inductively coupled plasma atomic emission spectrometric detection. The operating conditions (chemical and physical parameters) and the concentrations of the acids studied were evaluated for the efficient generation of BiH3 (bismuthine). Kinetic information about the decomposition process of BiH3 was also obtained. Analytical figures of merit including detection limits, precision and linear dynamic ranges are given for the six acids employed. The detection limits for Bi ranged between 0.3 and 0.7 µg l–1 depending on the acid used to generate BiH3. Compared with conventional continuous nebulization, the present coupling gives a sensitivity increase of approximately two orders of magnitude. The interfering effect of transition metals (Cd, Co, Cu, Cr, Fe, Mn, Ni, Zn), other hydride-forming elements (As, Ge, Pb, Sb, Se, Sn, Te) and Hg on the Bi signal using the different acids studied was evaluated. Tartaric acid is the most suitable reaction medium, in terms of efficiency in the hydride generation process and in the control of interferences. The proposed method was applied to the determination of Bi in certified reference materials (fresh water, silicate) and real environmental samples (iron ore and coal fly ash).Keywords
This publication has 18 references indexed in Scilit:
- Pre-concentration system for bismuth determination in urine using FI-ICP-AES with ultrasonic nebulizationJournal of Analytical Atomic Spectrometry, 1999
- Determination of As, Sb, Bi and Hg in water samples by flow-injection inductively coupled plasma mass spectrometry with an in-situ nebulizer/hydride generatorSpectrochimica Acta Part B: Atomic Spectroscopy, 1996
- Hydride Generation in Merging Chamber for Determination of Picogram Amounts of Bismuth by Inductively Coupled Plasma Mass SpectrometryAnalytical Sciences, 1990
- The determination of arsenic species by coupled high-performance liquid chromatography-atomic spectrometryAnalytical Proceedings including Analytical Communications, 1989
- In situ concentration of metallic hydride in a graphite furnace coated with palladium—determination of bismuth, germanium and telluriumSpectrochimica Acta Part B: Atomic Spectroscopy, 1989
- Determination of trace concentrations of bismuth by inductively coupled plasma-atomic emission spectrometry with hydride generationSpectrochimica Acta Part B: Atomic Spectroscopy, 1987
- Sorption and atomisation of metallic hydrides in a graphite furnaceJournal of Analytical Atomic Spectrometry, 1987
- Determination of bismuth in environmental samples by flameless atomic absorption spectrometry with hydride generationAnalytical Chemistry, 1982
- Non-dispersive atomic-fluorescence spectrometry of trace amounts of bismuth by introduction of its gaseous hydride into a premixed argon (entrained air)—hydrogen flameTalanta, 1979