Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: Influence of ionization type, sample preparation, and biofluid
Top Cited Papers
- 1 November 2003
- journal article
- Published by American Chemical Society (ACS)
- Vol. 14 (11) , 1290-1294
- https://doi.org/10.1016/s1044-0305(03)00574-9
Abstract
The purpose of the present work was to evaluate the synergistic effect of ionization type, sample preparation technique, and bio-fluid on the presence of matrix effect in quantitative liquid chromatography (LC)-MS/MS analysis of illicit drugs by post-column infusion experiments with morphine (10-µg/mL solution). Three bio-fluids (urine, oral fluid, and plasma) were pretreated with four sample preparation procedures [direct injection, dilution, protein precipitation, solid-phase extraction (SPE)] and analyzed by both LC-electrospray ionization (ESI)-MS/MS and LC-atmospheric pressure chemical ionization (APCI)-MS/MS. Our results indicated that both ionization types showed matrix effect, but ESI was more susceptible than APCI. Sample preparation could reduce (clean up) or magnify (pre-concentrate) matrix effect. Residual matrix components were specific to each bio-fluid and interfered at different time points in the chromatogram. We evaluated matrix effect in an early stage of method development and combined optimal ionization type and sample preparation technique for each bio-fluid. Simple dilution of urine was sufficient to allow for the analysis of the analytes of interest by LC-APCI-MS/MS. Acetonitrile protein precipitation provided both sample clean up and concentration for oral fluid analysis, while SPE was necessary for extensive clean up of plasma prior to LC-APCI-MS/MS.Keywords
This publication has 15 references indexed in Scilit:
- LC−Atmospheric Pressure Chemical Ionization-MS/MS Analysis of Multiple Illicit Drugs, Methadone, and Their Metabolites in Oral Fluid Following Protein PrecipitationAnalytical Chemistry, 2003
- Investigation of matrix effects in bioanalytical high‐performance liquid chromatography/tandem mass spectrometric assays: application to drug discoveryRapid Communications in Mass Spectrometry, 2002
- Matrix effects and selectivity issues in LC-MS-MSChromatographia, 2002
- The Use of LC-MS in Studies of Migration from Food Contact Materials: A Review of Present Applications and Future PossibilitiesCritical Reviews in Analytical Chemistry, 2002
- Quantitative screening and matrix effect studies of drug discovery compounds in monkey plasma using fast‐gradient liquid chromatography/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2001
- Mechanistic investigation of ionization suppression in electrospray ionizationPublished by American Chemical Society (ACS) ,2000
- Mechanistic aspects of electrospray ionizationJournal of Chromatography A, 1998
- Quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry: A study of ion suppressionJournal of the American Society for Mass Spectrometry, 1996
- From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometryAnalytical Chemistry, 1993
- Electrospray ionization–principles and practiceMass Spectrometry Reviews, 1990