Calibration of the UBVRI high-speed photometer of Laboratorio Nacionale de Astrofisica, Brazil
- 1 November 1994
- journal article
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 106 (705) , 1172
- https://doi.org/10.1086/133495
Abstract
We describe the characteristics and performance of a high-speed multicolor photometer, FOTRAP, which has been used since 1988 at LNA, Laboratorio Nacional de Astrofisicas/CNPq, Brazil. The opto-mechanical concepts, electronics and software are outlined. We discuss the quality and consistency of the transformations from the natural system to the UBVRI standard system. We give particular attention to the problem of transforming to the standard system observations of objects with blue spectra, like cataclysmic variables. We compare the results of our UBVRI measurements for a few spectrophotometric standards with the values published in the literature.Keywords
This publication has 0 references indexed in Scilit: