Metal on Metal Bearings in Hip Arthroplasty
- 1 August 1996
- journal article
- review article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 329, S11-S34
- https://doi.org/10.1097/00003086-199608001-00003
Abstract
Periprosthetic osteolysis caused by wear debris released from the bearing surface of polyethylene components is the major problem in contemporary hip arthroplasty. Several types of metal on metal prostheses were developed in the 1960s, but by the mid 1970s they were completely displaced by polyethylene bearings. There have been several generations of all metal components with significant variation in design, tolerances, and bearing surface quality. A number of these hips have survived for more than 25 years because of low wear rates and minimal osteolysis. Identification of the characteristics that contributed to long term function is important. The historical development and clinical results of metal on metal hip arthroplasties are presented. Factors that led to the abandonment of the metal on metal bearings are related to: (1) the early success of the Charnley prosthesis; (2) the frictional torque issue; (3) carcinogenesis concerns; (4) metal sensitivity concerns; (5) high infection rates; and (6) increased strain rates in periprosthetic bone and fatigue fractures of the acetabular floor. The accumulated experience to date enables one to evaluate all the factors with a different perspective and makes the use of newer metal on metal bearings a viable option in younger patients.Keywords
This publication has 52 references indexed in Scilit:
- Widespread dissemination of metal debris from implantsThe Journal of Bone and Joint Surgery. British volume, 1994
- Survivorship analysis of the ring hip arthroplastyThe Journal of Arthroplasty, 1991
- Prognosis of total hip replacementActa Orthopaedica, 1990
- Nine-year follow-up of the cementless Ring hipActa Orthopaedica, 1989
- Does corrosion matter?The Journal of Bone and Joint Surgery. British volume, 1988
- The McKee-Farrar hip arthroplasty. A long-term studyThe Journal of Bone and Joint Surgery. British volume, 1986
- Total Hip Replacement:A Ten-Year Follow-up of an Early SeriesActa Orthopaedica, 1982
- Aseptic Loosening of Cemented Total Arthroplasties of the Hip in Relation to Positioning of the Prosthesis:New Utilization of the Tschuprow-Cramer Statistical TestActa Orthopaedica, 1981
- Hip Replacement with the McKee-Farrar Prosthesis in Rheumatoid ArthritisActa Orthopaedica, 1980
- LOOSENING OF THE CEMENTED ACETABULAR CUP IN TOTAL HIP REPLACEMENTThe Journal of Bone and Joint Surgery. British volume, 1972