Comparison of a Hand-Held and Fixed Dynamometer in Measuring Strength of Patients With Neuromuscular Disease
- 1 February 1994
- journal article
- Published by Journal of Orthopaedic & Sports Physical Therapy (JOSPT) in Journal of Orthopaedic & Sports Physical Therapy
- Vol. 19 (2) , 100-104
- https://doi.org/10.2519/jospt.1994.19.2.100
Abstract
While numerous studies report acceptable reliability of hand-held dynamometers, very little information is available on factors affecting measurements and comparisons with other force measurement systems. A hand-held dynamometer was compared to a fixed dynamometer to determine if the two systems of force measurement yielded comparable results. Twenty-one patients with neuromuscular disease were measured for maximal isometric strength of 12 muscle groups with both force measurement systems using standardized positioning and stabilization procedures. Only one of the 12 muscle groups tested demonstrated significantly different force measurements between the two systems. Good association was found between both systems in force measurements, with Pearson correlation coefficients ranging from .76 to .90. We conclude that a hand-held dynamometer and a fixed dynamometer yield comparable results in patients with neuromuscular disease, provided that testing is limited to muscle groups producing relatively low forces.Keywords
This publication has 21 references indexed in Scilit:
- Intrasession and Intersession Reliability of Hand-held Dynamometer Measurements Taken on Brain-damaged PatientsPTJ: Physical Therapy & Rehabilitation Journal, 1989
- Make Tests and Break Tests of Elbow Flexor Muscle StrengthPTJ: Physical Therapy & Rehabilitation Journal, 1988
- Controlled acute trial of a thyrotrophin releasing hormone analogue (RX77368) in motor neuron disease.Journal of Neurology, Neurosurgery & Psychiatry, 1987
- Hand-held dynamometry; stability of muscle strength over multiple measurementsClinical Biomechanics, 1987
- Quantitative motor assessment in amyotrophic lateral sclerosisNeurology, 1986
- Test-Retest Reliability of Hand-Held Dynamometry During a Single Session of Strength AssessmentPTJ: Physical Therapy & Rehabilitation Journal, 1986
- The efficacy of manual assessment of muscle strength using a new deviceThe American Journal of Sports Medicine, 1982
- Reliability of Dynamometry in Patients with a Neuromuscular DisorderEngineering in Medicine, 1982
- Measurements of muscle strength and performance in children with normal and diseased muscle.Archives of Disease in Childhood, 1976
- HAND-HELD DYNAMOMETER FOR EVALUATING VOLUNTARY-MUSCLE FUNCTIONThe Lancet, 1974